Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,919
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0359 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,898 | $600 | Implemented |
SD0359 # 03 Y:2005 | 03 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,830 | $0 | Not Implemented |
SD0359 # 04 Y:2005 | 04 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,400 | $0 | Implemented |
SD0359 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $4,599 | $1,388 | Implemented |
SD0359 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,417 | $59,829 | Implemented |
SD0359 # 07 Y:2005 | 07 | 2005 | INSTALL SKYLIGHTS | $1,046 | $800 | Not Implemented |
SD0359 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $102 | $100 | Implemented |
SD0359 # 09 Y:2005 | 09 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $8,102 | $0 | Not Implemented |
SD0359 # 10 Y:2005 | 10 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,882 | $0 | Implemented |
UM0279 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,916 | $17,993 | Not Implemented |
UM0279 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,805 | $750 | Implemented |
UM0279 # 03 Y:2005 | 03 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,802 | $9,000 | Not Implemented |
UM0279 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,190 | $2,000 | Implemented |
UM0279 # 05 Y:2005 | 05 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,890 | $500 | Implemented |
UF0356 # 01 Y:2005 | 01 | 2005 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $0 | $150,000 | Not Implemented |
UF0356 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,843 | $21,108 | Implemented |
UF0356 # 03 Y:2005 | 03 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,348 | $2,000 | Implemented |
UF0356 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,008 | $700 | Implemented |
UF0356 # 05 Y:2005 | 05 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,918 | $1,185 | Not Implemented |
UF0356 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,295 | $2,194 | Implemented |
UF0356 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,232 | $1,450 | Implemented |
UF0356 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $96 | $245 | Implemented |
UF0356 # 09 Y:2005 | 09 | 2005 | RECYCLE FLUORESCENT LAMPS | $0 | $3,496 | Implemented |
IC0088 # 01 Y:2004 | 01 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,664 | $0 | Implemented |
IC0088 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,571 | $20,087 | Not Implemented |