Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,933
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0251 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,693 | $5,000 | Not Implemented |
SD0251 # 04 Y:2000 | 04 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,316 | $5,000 | Not Implemented |
SD0251 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,040 | $200 | Implemented |
SD0251 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,438 | $1,438 | Implemented |
SD0251 # 07 Y:2000 | 07 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $1,315 | $1,000 | Not Implemented |
SD0251 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,240 | $7,900 | Implemented |
SD0251 # 09 Y:2000 | 09 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $75,350 | $10,050 | Not Implemented |
OK0594 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,935 | $800 | Implemented |
OK0594 # 02 Y:2000 | 02 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,177 | $13,490 | Implemented |
OK0594 # 03 Y:2000 | 03 | 2000 | INSTALL SKYLIGHTS | $3,419 | $2,000 | Implemented |
OK0594 # 04 Y:2000 | 04 | 2000 | AUTOMATE FINISHING PROCESS | $137,280 | $200,000 | Not Implemented |
OK0594 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $3,339 | $860 | Implemented |
OK0594 # 06 Y:2000 | 06 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,028 | $0 | Not Implemented |
OK0594 # 07 Y:2000 | 07 | 2000 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $81,900 | $11,250 | Not Implemented |
OK0594 # 08 Y:2000 | 08 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,512 | $561 | Not Implemented |
OK0594 # 09 Y:2000 | 09 | 2000 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $8,320 | $0 | Not Implemented |
TP0013 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,107 | $850 | n/a |
TP0013 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,419 | $1,771 | n/a |
TP0013 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $2,151 | $1,175 | n/a |
TP0013 # 04 Y:2000 | 04 | 2000 | COMBINE UTILITY METERS | $1,560 | $0 | n/a |
TP0013 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $562 | $1,492 | n/a |
TP0013 # 06 Y:2000 | 06 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $181 | $67 | n/a |
TP0013 # 07 Y:2000 | 07 | 2000 | ADD AREA LIGHTING SWITCHES | $118 | $0 | n/a |
ME0281 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,872 | $44,461 | Not Implemented |
ME0281 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,085 | $3,826 | Not Implemented |