Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,933
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0349 # 04 Y:2019 | 04 | 2019 | REDUCE HEAT GAIN BY WINDOW TINTING | $9,207 | $13,256 | Not Implemented |
MI0349 # 05 Y:2019 | 05 | 2019 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,565 | $9,500 | Implemented |
MI0349 # 06 Y:2019 | 06 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,966 | $2,644 | Implemented |
MI0349 # 07 Y:2019 | 07 | 2019 | INSTALL OCCUPANCY SENSORS | $3,414 | $972 | Implemented |
MI0349 # 08 Y:2019 | 08 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,282 | $200 | Not Implemented |
MI0349 # 09 Y:2019 | 09 | 2019 | USE PHOTOCELL CONTROLS | $1,282 | $622 | Implemented |
SU0473 # 01 Y:2019 | 01 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,790 | $0 | Implemented |
SU0473 # 02 Y:2019 | 02 | 2019 | USE SYNTHETIC LUBRICANT | $11,804 | $0 | Not Implemented |
SU0473 # 03 Y:2019 | 03 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $519 | $200 | Implemented |
SU0473 # 04 Y:2019 | 04 | 2019 | USE PHOTOCELL CONTROLS | $916 | $470 | Not Implemented |
SU0473 # 05 Y:2019 | 05 | 2019 | REDUCE VENTILATION AIR | $660 | $925 | Not Implemented |
SU0473 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $192 | $290 | Implemented |
SU0473 # 07 Y:2019 | 07 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,625 | $4,006 | Not Implemented |
SU0473 # 08 Y:2019 | 08 | 2019 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $167 | $412 | Not Implemented |
SU0473 # 09 Y:2019 | 09 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,728 | $30,695 | Not Implemented |
CL1807 # 01 Y:2018 | 01 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $51,068 | $500 | Not Implemented |
CL1807 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $38,713 | $42,563 | Not Implemented |
CL1807 # 03 Y:2018 | 03 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,718 | $15,500 | Not Implemented |
CL1807 # 04 Y:2018 | 04 | 2018 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,717 | $3,050 | Not Implemented |
CL1807 # 05 Y:2018 | 05 | 2018 | REPLACE BOILER | $1,478 | $750 | Not Implemented |
UD0982 # 01 Y:2018 | 01 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $21,886 | $0 | Implemented |
UD0982 # 02 Y:2018 | 02 | 2018 | REDUCE VENTILATION AIR | $9,420 | $3,000 | Implemented |
UD0982 # 03 Y:2018 | 03 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,010 | $500 | Implemented |
UD0982 # 04 Y:2018 | 04 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,415 | $0 | Implemented |
UD0982 # 05 Y:2018 | 05 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,501 | $8,000 | Implemented |