Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0259 # 01 Y:1992 | 01 | 1992 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $8,134 | $0 | Not Implemented |
MA0259 # 02 Y:1992 | 02 | 1992 | BURN A LESS EXPENSIVE GRADE OF FUEL | $3,084 | $0 | Not Implemented |
MA0259 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $0 | Not Implemented |
MA0259 # 04 Y:1992 | 04 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $562 | $509 | Not Implemented |
MA0259 # 05 Y:1992 | 05 | 1992 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $686 | $2,108 | Not Implemented |
MA0259 # 06 Y:1992 | 06 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $584 | $0 | Not Implemented |
MA0259 # 07 Y:1992 | 07 | 1992 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $396 | $168 | Not Implemented |
MA0259 # 08 Y:1992 | 08 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $292 | $180 | Not Implemented |
ND0042 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $759 | $7,880 | Implemented |
ND0042 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,027 | $350 | Implemented |
ND0042 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $305 | $10,000 | Implemented |
ND0042 # 04 Y:1992 | 04 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $186 | $436 | Implemented |
ND0042 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $241 | $88 | Implemented |
ND0044 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $2,057 | $0 | Not Implemented |
ND0044 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $456 | $500 | Not Implemented |
ND0044 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $158 | $500 | Not Implemented |
ND0044 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $444 | $740 | Not Implemented |
ND0044 # 04 Y:1992 | 04 | 1992 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,038 | $300 | Not Implemented |
ND0044 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $438 | $3,450 | Not Implemented |
ND0044 # 01 Y:1992 | 01 | 1992 | OPTIMIZE PLANT POWER FACTOR | $4,301 | $2,421 | Not Implemented |
IA0030 # 03 Y:1992 | 03 | 1992 | USE RADIANT HEATER FOR SPOT HEATING | $4,443 | $12,690 | Implemented |
IA0030 # 01 Y:1992 | 01 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,403 | $29,569 | Not Implemented |
IA0030 # 09 Y:1992 | 09 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $383 | $200 | Implemented |
IA0030 # 08 Y:1992 | 08 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $357 | $4,230 | Implemented |
IA0030 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $169 | $300 | Not Implemented |