Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0632 # 04 Y:2001 | 04 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,915 | $0 | Implemented |
UD0632 # 03 Y:2001 | 03 | 2001 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $15,075 | $0 | Not Implemented |
UD0632 # 08 Y:2001 | 08 | 2001 | INSULATE BARE EQUIPMENT | $315 | $435 | Not Implemented |
UD0632 # 01 Y:2001 | 01 | 2001 | OPTIMIZE PLANT POWER FACTOR | $94,812 | $8,000 | Implemented |
UD0632 # 07 Y:2001 | 07 | 2001 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,355 | $0 | Not Implemented |
UD0632 # 05 Y:2001 | 05 | 2001 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $5,264 | $0 | Implemented |
UD0632 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,400 | $1,846 | Not Implemented |
UD0632 # 10 Y:2001 | 10 | 2001 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $207 | $300 | Not Implemented |
UD0632 # 02 Y:2001 | 02 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $33,500 | $6,000 | Not Implemented |
UD0632 # 09 Y:2001 | 09 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $307 | $12 | Not Implemented |
UM0191 # 05 Y:2001 | 05 | 2001 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,708 | $1,250 | Not Implemented |
UM0191 # 04 Y:2001 | 04 | 2001 | CONDENSE OPERATION INTO ONE BUILDING | $12,695 | $10,000 | Not Implemented |
UM0191 # 03 Y:2001 | 03 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,050 | $3,150 | Implemented |
UM0191 # 02 Y:2001 | 02 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $29,810 | $40,000 | Not Implemented |
UM0191 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,160 | $12,637 | Not Implemented |
UD0623 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $3,421 | $11,978 | Not Implemented |
UD0623 # 10 Y:2001 | 10 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $641 | $436 | Not Implemented |
UD0623 # 09 Y:2001 | 09 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $675 | $225 | Not Implemented |
UD0623 # 08 Y:2001 | 08 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $756 | $3,000 | Implemented |
UD0623 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,534 | $1,619 | Implemented |
UD0623 # 06 Y:2001 | 06 | 2001 | MINIMIZE WATER USAGE | $1,740 | $22 | Implemented |
UD0623 # 05 Y:2001 | 05 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,301 | $1,000 | Not Implemented |
UD0623 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $12,127 | $196 | Implemented |
UD0623 # 02 Y:2001 | 02 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $13,412 | $700 | Implemented |
UD0623 # 01 Y:2001 | 01 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $32,488 | $128,084 | Not Implemented |