Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
152
matching recommendationsSIC | 3544 | Special Dies, Tools, Jigs & Fixtures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0662 # 04 Y:2003 | 04 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,823 | $1,500 | Not Implemented |
UD0662 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,817 | $0 | Not Implemented |
UD0662 # 06 Y:2003 | 06 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $971 | $800 | Not Implemented |
UD0662 # 07 Y:2003 | 07 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $541 | $2,030 | Not Implemented |
UD0662 # 08 Y:2003 | 08 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $365 | $0 | Not Implemented |
UD0662 # 09 Y:2003 | 09 | 2003 | DISCONNECT BALLASTS | $328 | $65 | Not Implemented |
UD0662 # 10 Y:2003 | 10 | 2003 | INSTALL OCCUPANCY SENSORS | $204 | $549 | Not Implemented |
UD0662 # 11 Y:2003 | 11 | 2003 | USE PHOTOCELL CONTROLS | $172 | $154 | Implemented |
UD0662 # 12 Y:2003 | 12 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $81 | $0 | Not Implemented |
WV0238 # 13 Y:2002 | 13 | 2002 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $11,520 | $1,620 | Not Implemented |
WV0238 # 12 Y:2002 | 12 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,560 | $100 | Implemented |
WV0238 # 11 Y:2002 | 11 | 2002 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $2,080 | $100 | Implemented |
WV0238 # 10 Y:2002 | 10 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,562 | $150 | Implemented |
WV0238 # 09 Y:2002 | 09 | 2002 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $6,165 | $0 | Not Implemented |
WV0238 # 08 Y:2002 | 08 | 2002 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,813 | $0 | Implemented |
WV0238 # 07 Y:2002 | 07 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $649 | $450 | Implemented |
WV0238 # 06 Y:2002 | 06 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,806 | $0 | Implemented |
WV0238 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,894 | $2,910 | Implemented |
WV0238 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,250 | $315 | Implemented |
WV0238 # 03 Y:2002 | 03 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,462 | $188 | Not Implemented |
WV0238 # 02 Y:2002 | 02 | 2002 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $424 | $60 | Implemented |
WV0238 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,740 | $100 | Implemented |
UD0570 # 02 Y:1999 | 02 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $5,639 | $8,900 | Not Implemented |
UD0570 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,148 | $200 | Implemented |
UD0570 # 01 Y:1999 | 01 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $27,963 | $0 | Implemented |