20
matching recommendationsSIC | 3545 | Machine Tool Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CL1807 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $38,713 | $42,563 | Not Implemented |
CL1807 # 03 Y:2018 | 03 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,718 | $15,500 | Not Implemented |
CL1807 # 04 Y:2018 | 04 | 2018 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $3,717 | $3,050 | Not Implemented |
CL1807 # 05 Y:2018 | 05 | 2018 | REPLACE BOILER | $1,478 | $750 | Not Implemented |
CL1807 # 01 Y:2018 | 01 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $51,068 | $500 | Not Implemented |
TN0609 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $860 | $600 | Not Implemented |
TN0609 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $5,330 | $6,200 | Implemented |
TN0609 # 04 Y:1997 | 04 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $8,030 | $20,880 | Not Implemented |
TN0609 # 03 Y:1997 | 03 | 1997 | ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT | $10,970 | $5,080 | Not Implemented |
TN0609 # 02 Y:1997 | 02 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $64,970 | $45,880 | Not Implemented |
TN0609 # 01 Y:1997 | 01 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $83,060 | $19,080 | Not Implemented |
TN0424 # 07 Y:1991 | 07 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,927 | $390 | Implemented |
TN0424 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $1,885 | $0 | Implemented |
TN0424 # 09 Y:1991 | 09 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,501 | $1,340 | Implemented |
TN0424 # 06 Y:1991 | 06 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $2,594 | $0 | Implemented |
TN0424 # 05 Y:1991 | 05 | 1991 | IMPROVE LUBRICATION PRACTICES | $3,278 | $4,500 | Implemented |
TN0424 # 04 Y:1991 | 04 | 1991 | INSULATE BARE EQUIPMENT | $3,307 | $840 | Implemented |
TN0424 # 03 Y:1991 | 03 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,380 | $1,120 | Implemented |
TN0424 # 02 Y:1991 | 02 | 1991 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $11,182 | $17,000 | Implemented |
TN0424 # 01 Y:1991 | 01 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $29,757 | $8,500 | Implemented |