Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
741
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0457 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,863 | $567 | Implemented |
BD0457 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,919 | $8,320 | Implemented |
MI0269 # 01 Y:2014 | 01 | 2014 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $33,693 | $150,000 | Implemented |
MI0269 # 04 Y:2014 | 04 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,584 | $3,600 | Implemented |
MI0269 # 05 Y:2014 | 05 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,528 | $2,040 | Implemented |
MI0269 # 06 Y:2014 | 06 | 2014 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $3,491 | $9,600 | Implemented |
MI0269 # 07 Y:2014 | 07 | 2014 | INSTALL SKYLIGHTS | $2,957 | $500 | Implemented |
MI0269 # 08 Y:2014 | 08 | 2014 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,668 | $6,886 | Implemented |
MI0269 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,598 | $2,160 | Implemented |
MI0269 # 10 Y:2014 | 10 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,064 | $360 | Implemented |
MI0269 # 11 Y:2014 | 11 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $928 | $1,660 | Implemented |
MI0269 # 12 Y:2014 | 12 | 2014 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $140 | $20 | Implemented |
MI0269 # 13 Y:2014 | 13 | 2014 | INSTALL OCCUPANCY SENSORS | $51 | $80 | Implemented |
OK0897 # 07 Y:2014 | 07 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,545 | $3,641 | Implemented |
OK0897 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,792 | $1,656 | Implemented |
OK0897 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,000 | $10,067 | Implemented |
OK0897 # 04 Y:2014 | 04 | 2014 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $248 | $0 | Implemented |
OK0897 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,796 | $2,066 | Implemented |
OK0897 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,440 | $1,188 | Implemented |
OK0897 # 01 Y:2014 | 01 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,056 | $0 | Implemented |
LE0379 # 01 Y:2014 | 01 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,081 | $40 | Implemented |
LE0379 # 02 Y:2014 | 02 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $1,602 | $225 | Implemented |
LE0379 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $2,644 | $900 | Implemented |
LE0379 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $396 | $780 | Implemented |
UA0122 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,196 | $100 | Implemented |