Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
45
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0593 # 02 Y:2020 | 02 | 2020 | UPGRADE CONTROLS ON COMPRESSORS | $9,611 | $20,330 | Implemented |
WV0593 # 09 Y:2020 | 09 | 2020 | INSTALL OCCUPANCY SENSORS | $1,845 | $3,682 | Implemented |
WV0593 # 07 Y:2020 | 07 | 2020 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,437 | $4,000 | Not Implemented |
WV0593 # 08 Y:2020 | 08 | 2020 | DEVELOP A REPAIR/REPLACE POLICY | $1,877 | $318 | Implemented |
WV0593 # 06 Y:2020 | 06 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,451 | $44 | Implemented |
WV0593 # 05 Y:2020 | 05 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,139 | $1,114 | Implemented |
WV0593 # 04 Y:2020 | 04 | 2020 | RECYCLE WHITE WATER | $8,377 | $11,018 | Not Implemented |
WV0593 # 10 Y:2020 | 10 | 2020 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,826 | $3,500 | Not Implemented |
WV0593 # 11 Y:2020 | 11 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,741 | $1,284 | Implemented |
WV0593 # 01 Y:2020 | 01 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,054 | $69,828 | Implemented |
WV0593 # 03 Y:2020 | 03 | 2020 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,095 | $4,464 | Not Implemented |
LE0302 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $100,844 | $52,100 | Not Implemented |
LE0302 # 02 Y:2010 | 02 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $43,590 | $6,000 | Not Implemented |
LE0302 # 03 Y:2010 | 03 | 2010 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $19,885 | $35,220 | Not Implemented |
LE0302 # 04 Y:2010 | 04 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,289 | $6,000 | Not Implemented |
LE0302 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,786 | $1,720 | Implemented |
LE0302 # 06 Y:2010 | 06 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $46,342 | $10,000 | Implemented |
LE0302 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $18,237 | $12,000 | Not Implemented |
LE0302 # 08 Y:2010 | 08 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,646 | $480 | Implemented |
LE0302 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,383 | $15,780 | Not Implemented |
LE0302 # 10 Y:2010 | 10 | 2010 | INSTALL OCCUPANCY SENSORS | $1,414 | $300 | Not Implemented |
LE0201 # 03 Y:2004 | 03 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,356 | $2,500 | Implemented |
LE0201 # 07 Y:2004 | 07 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,924 | $2,115 | Implemented |
LE0201 # 04 Y:2004 | 04 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,622 | $450 | Not Implemented |
LE0201 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,994 | $0 | Implemented |