Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
87
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0330 # 07 Y:1998 | 07 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,707 | $15,000 | Not Implemented |
WI0330 # 06 Y:1998 | 06 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $8,769 | $4,000 | Not Implemented |
WI0330 # 05 Y:1998 | 05 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $5,622 | $0 | Not Implemented |
WI0330 # 04 Y:1998 | 04 | 1998 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $11,095 | $0 | Implemented |
WI0330 # 02 Y:1998 | 02 | 1998 | $71,911 | $100,000 | Not Implemented | |
WI0330 # 01 Y:1998 | 01 | 1998 | $225,000 | $10,000 | Implemented | |
WI0330 # 12 Y:1998 | 12 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $873 | $3,000 | Not Implemented |
SD0205 # 04 Y:1998 | 04 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,039 | $195 | Implemented |
SD0205 # 01 Y:1998 | 01 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $11,008 | $12,000 | Not Implemented |
SD0205 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,896 | $1,029 | Not Implemented |
SD0205 # 03 Y:1998 | 03 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,819 | $620 | Not Implemented |
SD0205 # 08 Y:1998 | 08 | 1998 | $19,800 | $8,000 | Not Implemented | |
SD0205 # 10 Y:1998 | 10 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $24,243 | $3,300 | Not Implemented |
SD0205 # 09 Y:1998 | 09 | 1998 | $14,850 | $1,200 | Not Implemented | |
SD0205 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $727 | $0 | Implemented |
SD0205 # 06 Y:1998 | 06 | 1998 | RECYCLE WHITE WATER | $180,189 | $400,000 | Implemented |
SD0205 # 07 Y:1998 | 07 | 1998 | $336,172 | $311,000 | Not Implemented | |
CO0418 # 02 Y:1998 | 02 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,800 | $700 | Implemented |
CO0418 # 06 Y:1998 | 06 | 1998 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $210 | $0 | Not Implemented |
CO0418 # 05 Y:1998 | 05 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,130 | $500 | Not Implemented |
CO0418 # 04 Y:1998 | 04 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $7,100 | $0 | Not Implemented |
CO0418 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $640 | $330 | Implemented |
CO0418 # 01 Y:1998 | 01 | 1998 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,020 | $2,000 | Implemented |
CO0418 # 07 Y:1998 | 07 | 1998 | $10,560 | $4,510 | Implemented | |
DS0115 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $2,850 | $930 | Implemented |