IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

70

matching recommendations
Reset
SIC 3559 Special Industry Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0177 # 02 Y:1999 02 1999 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $88,107 $21,913 Implemented
SF0177 # 03 Y:1999 03 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,195 $2,425 Implemented
SF0177 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,353 $51,620 Implemented
SF0177 # 06 Y:1999 06 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $818 $0 Implemented
SF0177 # 05 Y:1999 05 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $8,353 $18,000 Not Implemented
SD0205 # 02 Y:1998 02 1998 INSTALL TIMERS AND/OR THERMOSTATS $1,896 $1,029 Not Implemented
SD0205 # 01 Y:1998 01 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $11,008 $12,000 Not Implemented
SD0205 # 03 Y:1998 03 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,819 $620 Not Implemented
SD0205 # 04 Y:1998 04 1998 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,039 $195 Implemented
SD0205 # 05 Y:1998 05 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $727 $0 Implemented
SD0205 # 06 Y:1998 06 1998 RECYCLE WHITE WATER $180,189 $400,000 Implemented
SD0205 # 07 Y:1998 07 1998 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $336,172 $311,000 Not Implemented
SD0205 # 08 Y:1998 08 1998 MOVE PRODUCT USING MECHANICAL MEANS $19,800 $8,000 Not Implemented
SD0205 # 09 Y:1998 09 1998 MOVE PRODUCT USING MECHANICAL MEANS $14,850 $1,200 Not Implemented
SD0205 # 10 Y:1998 10 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $24,243 $3,300 Not Implemented
NV0076 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $134 $37 Implemented
NV0076 # 08 Y:1997 08 1997 METER WASTE WATER $1,905 $4,000 Not Implemented
NV0076 # 07 Y:1997 07 1997 REGENERATE CLEANING SOLVENT ON-SITE AND REUSE $30,371 $47,825 Not Implemented
NV0076 # 06 Y:1997 06 1997 RECOVER WASTE HEAT FROM EQUIPMENT $7,229 $4,000 Not Implemented
NV0076 # 05 Y:1997 05 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,980 $800 Not Implemented
NV0076 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,956 $1,911 Not Implemented
NV0076 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $729 $327 Not Implemented
NV0076 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,161 $300 Implemented
SF0073 # 06 Y:1995 06 1995 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $8,080 $2,950 Not Implemented
SF0073 # 07 Y:1995 07 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $2,735 $1,768 Not Implemented