Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,257

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0366 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,251 $20,735 Implemented
WV0366 # 02 Y:2007 02 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,342 $0 Implemented
WV0366 # 03 Y:2007 03 2007 RECOVER WASTE HEAT FROM EQUIPMENT $7,515 $540 Not Implemented
WV0366 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,238 $5,148 Implemented
WV0366 # 05 Y:2007 05 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,696 $1,315 Implemented
WV0366 # 06 Y:2007 06 2007 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,275 $7,600 Not Implemented
WV0366 # 07 Y:2007 07 2007 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,217 $1,000 Not Implemented
WV0366 # 08 Y:2007 08 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,400 $1,050 Implemented
WV0366 # 09 Y:2007 09 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,252 $0 Implemented
WV0366 # 10 Y:2007 10 2007 DEVELOP A REPAIR/REPLACE POLICY $2,440 $898 Implemented
WV0366 # 11 Y:2007 11 2007 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,157 $1,030 Not Implemented
WV0366 # 12 Y:2007 12 2007 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,770 $5,600 Not Implemented
WV0366 # 13 Y:2007 13 2007 OPTIMIZE PLANT POWER FACTOR $1,723 $5,600 Not Implemented
WV0366 # 14 Y:2007 14 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,641 $165 Not Implemented
WV0366 # 15 Y:2007 15 2007 UTILIZE A LESS EXPENSIVE COOLING METHOD $751 $1,641 Not Implemented
WV0366 # 16 Y:2007 16 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $667 $282 Implemented
UA0010 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,084 $70,481 Implemented
UA0010 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,004 $14,292 Implemented
UA0010 # 03 Y:2007 03 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $742 $0 Not Implemented
UA0010 # 04 Y:2007 04 2007 INSTALL TIMERS AND/OR THERMOSTATS $426 $590 Implemented
UA0010 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,616 $700 Implemented
UA0010 # 06 Y:2007 06 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $96 $528 Implemented
UA0010 # 07 Y:2007 07 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $933 $0 Implemented
UA0010 # 08 Y:2007 08 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $155 $320 Implemented
UW0004 # 01 Y:2007 01 2007 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $13,962 $8,762 Implemented