IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

432

matching recommendations
Reset
SIC 3562 Ball And Roller Bearings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0390 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,790 $72,987 Implemented
WV0390 # 03 Y:2009 03 2009 OPTIMIZE PLANT POWER FACTOR $20,264 $4,490 Implemented
WV0390 # 04 Y:2009 04 2009 USE RADIANT HEATER FOR SPOT HEATING $20,144 $22,048 Not Implemented
WV0390 # 05 Y:2009 05 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $16,484 $11,250 Not Implemented
WV0390 # 06 Y:2009 06 2009 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $15,354 $2,490 Implemented
WV0390 # 07 Y:2009 07 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,020 $2,500 Implemented
WV0390 # 08 Y:2009 08 2009 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,650 $0 Implemented
WV0390 # 09 Y:2009 09 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,395 $0 Implemented
WV0390 # 10 Y:2009 10 2009 RECOVER WASTE HEAT FROM EQUIPMENT $5,698 $3,136 Not Implemented
WV0390 # 11 Y:2009 11 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,238 $4,744 Implemented
WV0390 # 12 Y:2009 12 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,219 $582 Not Implemented
WV0390 # 13 Y:2009 13 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $246 $326 Implemented
IC0145 # 07 Y:2008 07 2008 DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS $2,172 $4,500 Not Implemented
IC0145 # 09 Y:2008 09 2008 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $611 $0 Not Implemented
IC0145 # 08 Y:2008 08 2008 CONDENSE OPERATION INTO ONE BUILDING $3,114 $0 Not Implemented
IC0145 # 06 Y:2008 06 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $466 $3,785 Not Implemented
IC0145 # 05 Y:2008 05 2008 INSTALL OCCUPANCY SENSORS $7,958 $14,655 Not Implemented
IC0145 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,134 $391 Not Implemented
IC0145 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,604 $14,300 Not Implemented
IC0145 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $556 $4,664 Not Implemented
IC0145 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $57,047 $112,631 Not Implemented
IC0140 # 11 Y:2008 11 2008 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $9,973 $0 Not Implemented
IC0140 # 10 Y:2008 10 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,616 $0 Not Implemented
IC0140 # 09 Y:2008 09 2008 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $135 $0 Not Implemented
IC0140 # 08 Y:2008 08 2008 USE OPTIMUM THICKNESS INSULATION $19,374 $4,100 Not Implemented