Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
686
matching recommendationsSIC | 3564 | Blowers And Fans |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0366 # 07 Y:2007 | 07 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,217 | $1,000 | Not Implemented |
WV0366 # 06 Y:2007 | 06 | 2007 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,275 | $7,600 | Not Implemented |
WV0366 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,696 | $1,315 | Implemented |
WV0366 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,238 | $5,148 | Implemented |
WV0366 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,515 | $540 | Not Implemented |
WV0366 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,342 | $0 | Implemented |
WV0366 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,251 | $20,735 | Implemented |
WV0366 # 15 Y:2007 | 15 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $751 | $1,641 | Not Implemented |
WV0366 # 14 Y:2007 | 14 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,641 | $165 | Not Implemented |
WV0366 # 13 Y:2007 | 13 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,723 | $5,600 | Not Implemented |
WV0366 # 12 Y:2007 | 12 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,770 | $5,600 | Not Implemented |
UD0747 # 01 Y:2006 | 01 | 2006 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $182,400 | $85,000 | Not Implemented |
UD0747 # 02 Y:2006 | 02 | 2006 | DEVELOP STANDARD OPERATING PROCEDURES | $29,600 | $32,000 | Implemented |
UD0747 # 03 Y:2006 | 03 | 2006 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $23,000 | $1,200 | Not Implemented |
UD0747 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,997 | $22,960 | Not Implemented |
UD0747 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,322 | $14,256 | Implemented |
UD0747 # 06 Y:2006 | 06 | 2006 | USE OPTIMUM THICKNESS INSULATION | $4,800 | $9,030 | Not Implemented |
UD0747 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $3,215 | $1,995 | Not Implemented |
UD0747 # 08 Y:2006 | 08 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $3,095 | $760 | Not Implemented |
UD0747 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,678 | $0 | Not Implemented |
UD0747 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,554 | $4,920 | Not Implemented |
UD0747 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,209 | $1,800 | Not Implemented |
UD0747 # 12 Y:2006 | 12 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $920 | $0 | Not Implemented |
UD0747 # 13 Y:2006 | 13 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $909 | $1,000 | Not Implemented |
UD0747 # 14 Y:2006 | 14 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $480 | $81 | Not Implemented |