IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

676

matching recommendations
Reset
SIC 3564 Blowers And Fans
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0395 # 07 Y:2001 07 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $935 $640 Not Implemented
WI0395 # 08 Y:2001 08 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $163 $60 Not Implemented
WI0395 # 01 Y:2001 01 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $11,007 $0 Not Implemented
WI0395 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,031 $17,436 n/a
WI0395 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $1,563 $1,800 Implemented
WI0395 # 04 Y:2001 04 2001 INSTALL OCCUPANCY SENSORS $320 $350 Implemented
SD0266 # 01 Y:2001 01 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,560 $5,000 Not Implemented
SD0266 # 02 Y:2001 02 2001 INSTALL SKYLIGHTS $8,646 $16,500 Not Implemented
SD0266 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,892 $210 Not Implemented
SD0266 # 04 Y:2001 04 2001 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,776 $1,500 Not Implemented
SD0266 # 05 Y:2001 05 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $517 $100 Not Implemented
SD0266 # 06 Y:2001 06 2001 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $158,100 $114,362 Not Implemented
SD0266 # 07 Y:2001 07 2001 INSTALL EQUIPMENT TO MOVE PRODUCT $52,020 $10,000 Not Implemented
SD0266 # 08 Y:2001 08 2001 INSTALL AUTOMATIC PACKING EQUIPMENT $6,772 $3,400 Implemented
WV0204 # 11 Y:2000 11 2000 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $1,992 $34 Not Implemented
WV0204 # 15 Y:2000 15 2000 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $72,800 $140,000 Not Implemented
WV0204 # 14 Y:2000 14 2000 IMPROVE SPACE COMFORT CONDITIONING $20,000 $500 Not Implemented
WV0204 # 13 Y:2000 13 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,081 $5,000 Not Implemented
WV0204 # 12 Y:2000 12 2000 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $1,902 $5,604 Not Implemented
WV0204 # 10 Y:2000 10 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $705 $75 Implemented
WV0204 # 09 Y:2000 09 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,607 $680 Implemented
WV0204 # 08 Y:2000 08 2000 ISOLATE HOT OR COLD EQUIPMENT $996 $1,500 Not Implemented
WV0204 # 07 Y:2000 07 2000 USE SYNTHETIC LUBRICANT $656 $334 Implemented
WV0204 # 06 Y:2000 06 2000 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $2,627 $680 Implemented
WV0204 # 05 Y:2000 05 2000 INSULATE BARE EQUIPMENT $12,395 $2,180 Implemented