Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

55

matching recommendations
Reset
SIC 3564 Blowers And Fans
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0647 # 05 Y:2020 05 2020 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $124,057 $600,000 Not Implemented
NC0647 # 04 Y:2020 04 2020 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $20,880 $5,000 Not Implemented
NC0647 # 03 Y:2020 03 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $192 $135 Not Implemented
NC0647 # 02 Y:2020 02 2020 INSTALL OCCUPANCY SENSORS $2,488 $5,708 Not Implemented
NC0647 # 01 Y:2020 01 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,099 $20,000 Not Implemented
NC0530 # 05 Y:2014 05 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,542 $5,000 Not Implemented
NC0530 # 13 Y:2014 13 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $763 $2,400 Not Implemented
NC0530 # 14 Y:2014 14 2014 DEVELOP A REPAIR/REPLACE POLICY $2,001 $4,256 Implemented
NC0530 # 01 Y:2014 01 2014 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $14,069 $54,000 Not Implemented
NC0530 # 02 Y:2014 02 2014 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $1,055 $0 Implemented
NC0530 # 03 Y:2014 03 2014 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,962 $200 Implemented
NC0530 # 04 Y:2014 04 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,946 $18,000 Not Implemented
NC0530 # 12 Y:2014 12 2014 USE PHOTOCELL CONTROLS $341 $80 Not Implemented
NC0530 # 06 Y:2014 06 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $443 $200 Implemented
NC0530 # 07 Y:2014 07 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,767 $4,000 Not Implemented
NC0530 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,623 $2,350 Implemented
NC0530 # 09 Y:2014 09 2014 INSTALL OCCUPANCY SENSORS $2,127 $6,420 Not Implemented
NC0530 # 10 Y:2014 10 2014 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $686 $563 Implemented
NC0530 # 11 Y:2014 11 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $632 $176 Implemented
NC0497 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $13,386 $2,785 Implemented
NC0497 # 04 Y:2013 04 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,827 $11,647 Implemented
NC0497 # 06 Y:2013 06 2013 USE PHOTOCELL CONTROLS $2,032 $120 Not Implemented
NC0497 # 07 Y:2013 07 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,053 $513 Implemented
NC0497 # 08 Y:2013 08 2013 DEVELOP A REPAIR/REPLACE POLICY $3,513 $4,256 Implemented
NC0497 # 09 Y:2013 09 2013 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $360 $650 Implemented