IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

54

matching recommendations
Reset
SIC 3564 Blowers And Fans
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0366 # 16 Y:2007 16 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $667 $282 Implemented
WV0366 # 10 Y:2007 10 2007 DEVELOP A REPAIR/REPLACE POLICY $2,440 $898 Implemented
WV0366 # 09 Y:2007 09 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,252 $0 Implemented
WV0366 # 08 Y:2007 08 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,400 $1,050 Implemented
WV0366 # 07 Y:2007 07 2007 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,217 $1,000 Not Implemented
WV0366 # 06 Y:2007 06 2007 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,275 $7,600 Not Implemented
WV0366 # 05 Y:2007 05 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,696 $1,315 Implemented
WV0366 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,238 $5,148 Implemented
WV0366 # 03 Y:2007 03 2007 RECOVER WASTE HEAT FROM EQUIPMENT $7,515 $540 Not Implemented
WV0366 # 11 Y:2007 11 2007 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,157 $1,030 Not Implemented
WV0366 # 02 Y:2007 02 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,342 $0 Implemented
WV0366 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,251 $20,735 Implemented
WV0366 # 12 Y:2007 12 2007 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,770 $5,600 Not Implemented
WV0366 # 14 Y:2007 14 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,641 $165 Not Implemented
WV0366 # 15 Y:2007 15 2007 UTILIZE A LESS EXPENSIVE COOLING METHOD $751 $1,641 Not Implemented
WV0366 # 13 Y:2007 13 2007 OPTIMIZE PLANT POWER FACTOR $1,723 $5,600 Not Implemented
UD0674 # 15 Y:2003 15 2003 DISCONNECT BALLASTS $313 $44 Implemented
UD0674 # 13 Y:2003 13 2003 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $475 $350 Not Implemented
UD0674 # 11 Y:2003 11 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $509 $142 Not Implemented
UD0674 # 10 Y:2003 10 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $554 $2,200 Implemented
UD0674 # 14 Y:2003 14 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $360 $100 Implemented
UD0674 # 08 Y:2003 08 2003 ADD AREA LIGHTING SWITCHES $687 $500 Not Implemented
UD0674 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,100 $3,078 Not Implemented
UD0674 # 01 Y:2003 01 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $18,633 $45,760 Not Implemented
UD0674 # 02 Y:2003 02 2003 $8,166 $30,000 Implemented