IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

30

matching recommendations
Reset
SIC 3566 Speed Changers, Drives, And Gears
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0271 # 06 Y:2003 06 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $796 $100 Implemented
NC0271 # 05 Y:2003 05 2003 DEVELOP A REPAIR/REPLACE POLICY $204 $150 Implemented
NC0271 # 04 Y:2003 04 2003 ADOPT IN-HOUSE MATERIAL GENERATION $56,248 $120,000 Not Implemented
NC0271 # 03 Y:2003 03 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $18,792 $27,000 Not Implemented
NC0271 # 02 Y:2003 02 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $9,935 $4,065 Not Implemented
NC0271 # 01 Y:2003 01 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,523 $50 Implemented
IC0070 # 08 Y:2003 08 2003 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $73,846 $613,200 Not Implemented
IC0070 # 07 Y:2003 07 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $58,133 $0 Implemented
IC0070 # 06 Y:2003 06 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $56,367 $4,200 Implemented
IC0070 # 05 Y:2003 05 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,377 $0 Not Implemented
IC0070 # 04 Y:2003 04 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $51,638 $160,788 Not Implemented
IC0070 # 03 Y:2003 03 2003 INSTALL OCCUPANCY SENSORS $8,874 $22,864 Not Implemented
IC0070 # 02 Y:2003 02 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,127 $2,716 Not Implemented
IC0070 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,895 $46,610 Not Implemented
IC0068 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $919 $5,605 Not Implemented
IC0068 # 06 Y:2003 06 2003 UPGRADE OBSOLETE EQUIPMENT $84 $179 Not Implemented
IC0068 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $701 $1,279 Not Implemented
IC0068 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $717 $2,397 Not Implemented
IC0068 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,566 $12,133 Not Implemented
IC0068 # 02 Y:2003 02 2003 INSTALL TIMERS AND/OR THERMOSTATS $3,197 $855 Not Implemented
IC0068 # 01 Y:2003 01 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,412 $0 Not Implemented
IC0067 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,779 $2,600 Implemented
IC0067 # 09 Y:2003 09 2003 REDUCE OR ELIMINATE WASTE $13,650 $2,107 Not Implemented
IC0067 # 08 Y:2003 08 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $13,670 $0 Not Implemented
IC0067 # 07 Y:2003 07 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,728 $19,284 Not Implemented