IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

23

matching recommendations
Reset
SIC 3569 General Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0942 # 07 Y:2020 07 2020 USE SOLAR HEAT TO MAKE ELECTRICTY $114,607 $699,103 Not Implemented
GT0942 # 06 Y:2020 06 2020 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $113,048 $690,000 Not Implemented
GT0942 # 05 Y:2020 05 2020 MINIMIZE WATER USAGE $3,202 $5,700 Not Implemented
GT0942 # 04 Y:2020 04 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $50,179 $71,763 Not Implemented
GT0942 # 03 Y:2020 03 2020 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $14,945 $4,781 Not Implemented
GT0942 # 02 Y:2020 02 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,618 $2,500 Implemented
GT0942 # 01 Y:2020 01 2020 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $20,227 $1,450 Implemented
GT0802 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,610 $2,800 Not Implemented
GT0802 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,780 $5,000 Implemented
GT0802 # 06 Y:2005 06 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,100 $0 Implemented
GT0802 # 05 Y:2005 05 2005 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,820 $60 Not Implemented
GT0802 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,610 $6,510 Implemented
GT0802 # 02 Y:2005 02 2005 USE RADIANT HEATER FOR SPOT HEATING $18,100 $10,800 Implemented
GT0802 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $220 $300 Implemented
GT0644 # 01 Y:1998 01 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $303 $0 Implemented
GT0644 # 09 Y:1998 09 1998 CONDENSE OPERATION INTO ONE BUILDING $6,516 $0 Implemented
GT0644 # 08 Y:1998 08 1998 FILTER AND REUSE HYDRAULIC OIL $7,448 $4,500 Not Implemented
GT0644 # 07 Y:1998 07 1998 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $21,400 $32,860 Not Implemented
GT0644 # 06 Y:1998 06 1998 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $12,300 $2,000 Not Implemented
GT0644 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,160 $750 Implemented
GT0644 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,049 $5,558 Not Implemented
GT0644 # 03 Y:1998 03 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $6,251 $0 Implemented
GT0644 # 02 Y:1998 02 1998 COVER OPEN TANKS $6,346 $1,838 Not Implemented