Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

442

matching recommendations
Reset
SIC 357 Computer And Office Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0324 # 05 Y:2012 05 2012 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,357 $5,371 Not Implemented
SU0324 # 06 Y:2012 06 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $426 $777 Not Implemented
SU0324 # 07 Y:2012 07 2012 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,282 $6,008 Implemented
SU0324 # 08 Y:2012 08 2012 USE OTHER WASTE CONCENTRATION METHODS $5,924 $18,000 Not Implemented
IA0443 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,934 $20,207 Implemented
IA0443 # 02 Y:2009 02 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,968 $3,879 Implemented
IA0443 # 03 Y:2009 03 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,000 $152 Not Implemented
IA0443 # 04 Y:2009 04 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,636 $860 Not Implemented
IA0443 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,745 $256 Implemented
IA0443 # 06 Y:2009 06 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,145 $50 Not Implemented
IA0443 # 07 Y:2009 07 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,188 $500 Not Implemented
IA0443 # 08 Y:2009 08 2009 OPTIMIZE PLANT POWER FACTOR $4,398 $4,659 Implemented
IA0443 # 09 Y:2009 09 2009 USE OPTIMUM THICKNESS INSULATION $14,294 $11,978 Not Implemented
IA0443 # 10 Y:2009 10 2009 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,934 $20,000 Not Implemented
IA0443 # 11 Y:2009 11 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $377 $65 Implemented
SU0274 # 01 Y:2009 01 2009 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $11,264 $0 Not Implemented
SU0274 # 02 Y:2009 02 2009 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,328 $0 Not Implemented
SU0274 # 03 Y:2009 03 2009 USE SYNTHETIC LUBRICANT $545 $0 Implemented
SU0274 # 04 Y:2009 04 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $498 $0 Implemented
SU0274 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,346 $400 Implemented
SU0274 # 06 Y:2009 06 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $316 $204 Implemented
SU0274 # 07 Y:2009 07 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $341 $268 Not Implemented
SU0274 # 08 Y:2009 08 2009 INSTALL OCCUPANCY SENSORS $534 $595 Not Implemented
SU0274 # 09 Y:2009 09 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,444 $21,840 Not Implemented
SU0274 # 10 Y:2009 10 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $458 $720 Not Implemented