Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
133
matching recommendationsSIC | 358 | Refrigeration And Service Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0864 # 01 Y:2009 | 01 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $6,717 | $0 | Not Implemented |
GT0864 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,440 | $3,700 | Not Implemented |
GT0864 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $17,020 | $31,520 | Not Implemented |
GT0864 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,083 | $90,000 | Not Implemented |
GT0864 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,718 | $61,839 | Not Implemented |
GT0864 # 06 Y:2009 | 06 | 2009 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $17,955 | $22,473 | Not Implemented |
GT0864 # 07 Y:2009 | 07 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $56,030 | $107,040 | Not Implemented |
GT0858 # 01 Y:2008 | 01 | 2008 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $5,046 | $0 | Implemented |
GT0858 # 02 Y:2008 | 02 | 2008 | Equipment Scheduling | $5,630 | $0 | Not Implemented |
GT0858 # 03 Y:2008 | 03 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $16,189 | $33,180 | Implemented |
GT0858 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,485 | $4,500 | Implemented |
GT0858 # 05 Y:2008 | 05 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,063 | $10,879 | Implemented |
GT0858 # 06 Y:2008 | 06 | 2008 | USE SOLAR HEAT TO HEAT WATER | $3,687 | $7,500 | Not Implemented |
GT0858 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $475 | $900 | Not Implemented |
GT0858 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,520 | $5,835 | Not Implemented |
GT0809 # 01 Y:2005 | 01 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $15,771 | $0 | Implemented |
GT0809 # 02 Y:2005 | 02 | 2005 | USE SYNTHETIC LUBRICANT | $7,490 | $0 | Not Implemented |
GT0809 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,600 | $10,000 | Implemented |
GT0809 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,513 | $1,475 | Implemented |
GT0809 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,160 | $2,180 | n/a |
GT0809 # 06 Y:2005 | 06 | 2005 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,596 | $0 | n/a |
GT0809 # 07 Y:2005 | 07 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,741 | $10,484 | n/a |
GT0809 # 08 Y:2005 | 08 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $305 | $700 | n/a |
GT0809 # 09 Y:2005 | 09 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,388 | $35,680 | n/a |
GT0809 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,948 | $39,765 | n/a |