Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,655
matching recommendationsSIC | 358 | Refrigeration And Service Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0397 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $1,025 | $2,400 | Not Implemented |
WI0397 # 06 Y:2001 | 06 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $813 | $0 | Implemented |
WI0397 # 07 Y:2001 | 07 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $650 | $640 | Implemented |
WI0397 # 08 Y:2001 | 08 | 2001 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $502 | $0 | Implemented |
OK0614 # 01 Y:2001 | 01 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,325 | $335 | Not Implemented |
OK0614 # 02 Y:2001 | 02 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,500 | $6,100 | Not Implemented |
OK0614 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $5,656 | $9,700 | Implemented |
OK0614 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $377 | $3,700 | Not Implemented |
OK0614 # 05 Y:2001 | 05 | 2001 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $9,100 | $4,000 | Implemented |
IC0001 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,732 | $0 | Implemented |
IC0001 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,032 | $700 | Implemented |
IC0001 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,387 | $2,500 | Implemented |
IC0001 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $855 | $0 | Implemented |
IC0001 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $1,478 | $3,204 | Implemented |
IC0001 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $228 | $1,370 | Implemented |
IC0001 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,986 | $68,895 | Implemented |
IC0001 # 08 Y:2001 | 08 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,227 | $3,266 | Implemented |
IC0001 # 09 Y:2001 | 09 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $110,160 | $64 | Not Implemented |
IC0001 # 10 Y:2001 | 10 | 2001 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $367,200 | $826,000 | Not Implemented |
IC0001 # 11 Y:2001 | 11 | 2001 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $612,000 | $900,000 | Not Implemented |
IC0001 # 12 Y:2001 | 12 | 2001 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $300,000 | $840,000 | Implemented |
AM0393 # 01 Y:2001 | 01 | 2001 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $10,300 | $0 | Not Implemented |
AM0393 # 02 Y:2001 | 02 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $20,850 | $5,500 | Not Implemented |
AM0393 # 03 Y:2001 | 03 | 2001 | INSTALL SKYLIGHTS | $4,170 | $6,750 | Not Implemented |
AM0393 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $450 | $200 | Implemented |