Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsSIC | 3585 | Refrigeration And Heating Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0443 # 08 Y:1999 | 08 | 1999 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $31,200 | $8,000 | Implemented |
CO0443 # 06 Y:1999 | 06 | 1999 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,210 | $1,000 | Implemented |
CO0443 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,660 | $530 | Implemented |
CO0443 # 04 Y:1999 | 04 | 1999 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,760 | $2,000 | Implemented |
CO0443 # 03 Y:1999 | 03 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,900 | $250 | Implemented |
CO0443 # 01 Y:1999 | 01 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,960 | $0 | Implemented |
CO0278 # 04 Y:1993 | 04 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $14,570 | $2,700 | Implemented |
CO0278 # 07 Y:1993 | 07 | 1993 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $520 | $750 | Implemented |
CO0278 # 06 Y:1993 | 06 | 1993 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,120 | $8,160 | Implemented |
CO0278 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $530 | $250 | Implemented |
CO0278 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,760 | $710 | Implemented |
CO0278 # 01 Y:1993 | 01 | 1993 | REDUCE VENTILATION AIR | $6,130 | $1,560 | Implemented |
CO0049 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $614 | $1,050 | Implemented |
CO0049 # 09 Y:1985 | 09 | 1985 | IMPROVE LUBRICATION PRACTICES | $379 | $100 | Implemented |
CO0049 # 08 Y:1985 | 08 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,647 | $20,000 | Implemented |
CO0049 # 07 Y:1985 | 07 | 1985 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,828 | $2,800 | Implemented |
CO0049 # 06 Y:1985 | 06 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $296 | $250 | Implemented |
CO0049 # 05 Y:1985 | 05 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,347 | $200 | Implemented |
CO0049 # 04 Y:1985 | 04 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,411 | $4,000 | Implemented |
CO0049 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,488 | $300 | Implemented |