Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
429
matching recommendationsSIC | 3589 | Service Industry Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0148 # 04 Y:2002 | 04 | 2002 | OPTIMIZE PLANT POWER FACTOR | $5,475 | $10,500 | Implemented |
LL0148 # 05 Y:2002 | 05 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,293 | $0 | Not Implemented |
MI0025 # 01 Y:2001 | 01 | 2001 | RECOVER MECHANICAL ENERGY | $165,750 | $15,000 | Not Implemented |
MI0025 # 02 Y:2001 | 02 | 2001 | ELIMINATE A BY-PRODUCT | $35,000 | $100 | Not Implemented |
MI0025 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $492 | $2 | Not Implemented |
MI0025 # 04 Y:2001 | 04 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,050 | $100 | Implemented |
MI0025 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $1,778 | Implemented |
MS0190 # 01 Y:2001 | 01 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,911 | $6,300 | n/a |
MS0190 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $586 | $302 | n/a |
MS0190 # 03 Y:2001 | 03 | 2001 | OPTIMIZE PLANT POWER FACTOR | $9,338 | $9,000 | n/a |
MS0190 # 04 Y:2001 | 04 | 2001 | INSULATE BARE EQUIPMENT | $436 | $488 | n/a |
MS0190 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,525 | $5,299 | n/a |
MS0190 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,862 | $55,237 | n/a |
MS0190 # 07 Y:2001 | 07 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,869 | $96,000 | n/a |
MS0190 # 08 Y:2001 | 08 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,738 | $2,250 | n/a |
UF0279 # 01 Y:2001 | 01 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,057 | $10,208 | Implemented |
UF0279 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $696 | $660 | Not Implemented |
UF0279 # 03 Y:2001 | 03 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $20,871 | $62,226 | Not Implemented |
UF0279 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,241 | $1,520 | Implemented |
UF0279 # 05 Y:2001 | 05 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,260 | $0 | Implemented |
UF0279 # 06 Y:2001 | 06 | 2001 | INSTALL SKYLIGHTS | $2,897 | $3,188 | Not Implemented |
UF0279 # 07 Y:2001 | 07 | 2001 | INSTALL OCCUPANCY SENSORS | $2,853 | $767 | Implemented |
UF0279 # 08 Y:2001 | 08 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,800 | $0 | Implemented |
UF0279 # 09 Y:2001 | 09 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $6,500 | $4,612 | Implemented |
UF0275 # 01 Y:2001 | 01 | 2001 | INSTALL COMMON HEADER ON COMPRESSORS | $4,038 | $4,300 | Not Implemented |