Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsSIC | 359 | Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0039 # 02 Y:2009 | 02 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1 | $0 | Implemented |
TT0039 # 03 Y:2009 | 03 | 2009 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $77,380 | $7,000 | Implemented |
TT0039 # 04 Y:2009 | 04 | 2009 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $36,266 | $12,000 | Implemented |
TT0039 # 05 Y:2009 | 05 | 2009 | IMPROVE COMBUSTION CONTROL CAPABILITY | $112,568 | $64,000 | Not Implemented |
TT0039 # 06 Y:2009 | 06 | 2009 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,012 | $250 | Not Implemented |
TT0039 # 07 Y:2009 | 07 | 2009 | OPTIMIZE PLANT POWER FACTOR | $11,430 | $13,000 | Not Implemented |
TT0039 # 01 Y:2009 | 01 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,163 | $16,183 | Implemented |
OK0779 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,634 | $26,750 | Implemented |
OK0779 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,076 | $6,396 | Not Implemented |
OK0779 # 03 Y:2009 | 03 | 2009 | USE POWER DURING OFF-PEAK PERIODS | $30,940 | $0 | Not Implemented |
OK0779 # 02 Y:2009 | 02 | 2009 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $122,608 | $160,000 | Not Implemented |
OK0779 # 01 Y:2009 | 01 | 2009 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,513 | $900,000 | Not Implemented |
OK0779 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,089 | $14,467 | Implemented |
OK0779 # 07 Y:2009 | 07 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,569 | $0 | Implemented |
OK0779 # 08 Y:2009 | 08 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,812 | $1,944 | Implemented |
OK0779 # 09 Y:2009 | 09 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $7,677 | $989 | Not Implemented |
UD0794 # 08 Y:2009 | 08 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,202 | $0 | Implemented |
UD0794 # 07 Y:2009 | 07 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $3,255 | $0 | Implemented |
UD0794 # 09 Y:2009 | 09 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,223 | $1,000 | Implemented |
UD0794 # 04 Y:2009 | 04 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $9,841 | $10,000 | Not Implemented |
UD0794 # 01 Y:2009 | 01 | 2009 | REDESIGN PROCESS | $60,982 | $300,000 | Not Implemented |
UD0794 # 05 Y:2009 | 05 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,981 | $19,425 | Not Implemented |
UD0794 # 03 Y:2009 | 03 | 2009 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $20,779 | $50,000 | Not Implemented |
UD0794 # 02 Y:2009 | 02 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $46,758 | $0 | Not Implemented |
UD0794 # 06 Y:2009 | 06 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,273 | $1,000 | Not Implemented |