Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,456
matching recommendationsSIC | 359 | Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0057 # 08 Y:2010 | 08 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,029 | $12,535 | Not Implemented |
UA0057 # 07 Y:2010 | 07 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $3,185 | $1,020 | Not Implemented |
UA0057 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,400 | $2,080 | Implemented |
UA0057 # 05 Y:2010 | 05 | 2010 | USE PHOTOCELL CONTROLS | $8,910 | $1,742 | Not Implemented |
UA0057 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,876 | $3,000 | Implemented |
UA0057 # 06 Y:2010 | 06 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,885 | $250 | Not Implemented |
UA0057 # 02 Y:2010 | 02 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,848 | $80 | Implemented |
UA0057 # 04 Y:2010 | 04 | 2010 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $11,362 | $71,030 | Not Implemented |
LE0304 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,592 | $15,000 | Not Implemented |
LE0304 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,240 | $11,654 | Implemented |
LE0304 # 09 Y:2010 | 09 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,073 | $5,740 | Not Implemented |
LE0304 # 08 Y:2010 | 08 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,370 | $0 | Not Implemented |
LE0304 # 02 Y:2010 | 02 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $55,099 | $39,415 | Not Implemented |
LE0304 # 05 Y:2010 | 05 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $12,804 | $30 | Implemented |
LE0304 # 11 Y:2010 | 11 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,692 | $14,758 | Implemented |
LE0304 # 03 Y:2010 | 03 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,822 | $18,000 | Not Implemented |
LE0304 # 04 Y:2010 | 04 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,355 | $100,000 | Not Implemented |
LE0304 # 10 Y:2010 | 10 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $803 | $2,400 | Not Implemented |
LE0304 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,396 | $273 | Implemented |
LE0304 # 01 Y:2010 | 01 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $300,000 | $40,932 | Not Implemented |
OK0794 # 01 Y:2010 | 01 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $12,132 | $75,405 | Implemented |
OK0794 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,400 | $841 | Implemented |
OK0794 # 02 Y:2010 | 02 | 2010 | INSTALL SET-BACK TIMERS | $2,786 | $3,239 | Not Implemented |
OK0794 # 03 Y:2010 | 03 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $10,317 | $159,840 | Not Implemented |
OK0794 # 09 Y:2010 | 09 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $380 | $2,280 | Not Implemented |