Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 3599 | Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0348 # 08 Y:2004 | 08 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,653 | $4,596 | Implemented |
IA0348 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $383 | $120 | Not Implemented |
IA0348 # 06 Y:2004 | 06 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $193 | $438 | Not Implemented |
IA0348 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,829 | $14,216 | Implemented |
IA0348 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,888 | $535 | Implemented |
IA0348 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $651 | $146 | Implemented |
IA0348 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $9,818 | $10,704 | Implemented |
IA0348 # 02 Y:2004 | 02 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,336 | $475 | Not Implemented |
DS0161 # 07 Y:2000 | 07 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $1,560 | $3,000 | Not Implemented |
DS0161 # 08 Y:2000 | 08 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,203 | $0 | Implemented |
DS0161 # 06 Y:2000 | 06 | 2000 | BURN WASTE OIL FOR HEAT | $1,329 | $3,495 | Not Implemented |
DS0161 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $758 | $1,130 | Implemented |
DS0161 # 04 Y:2000 | 04 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $1,142 | $2,040 | Implemented |
DS0161 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,603 | $180 | Not Implemented |
DS0161 # 02 Y:2000 | 02 | 2000 | OPTIMIZE PLANT POWER FACTOR | $1,323 | $1,050 | Implemented |
DS0161 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,330 | $7,355 | Implemented |
IA0222 # 10 Y:1999 | 10 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $512 | $1,200 | Not Implemented |
IA0222 # 09 Y:1999 | 09 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $17,160 | $25,792 | Not Implemented |
IA0222 # 08 Y:1999 | 08 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $199,932 | $425,000 | Implemented |
IA0222 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,656 | $1,064 | Not Implemented |
IA0222 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $561 | $931 | Implemented |
IA0222 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $391 | $33 | Implemented |
IA0222 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $421 | $226 | Implemented |
IA0222 # 05 Y:1999 | 05 | 1999 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $5,097 | $3,584 | Not Implemented |
IA0222 # 06 Y:1999 | 06 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $3,600 | $900 | Implemented |