Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,559
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0306 # 03 Y:2008 | 03 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,949 | $1,716 | Not Implemented |
LL0306 # 04 Y:2008 | 04 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,767 | $90 | Implemented |
LL0306 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,728 | $880 | Implemented |
LL0306 # 06 Y:2008 | 06 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $701 | $10 | Not Implemented |
LL0306 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $256 | $375 | Not Implemented |
LL0306 # 08 Y:2008 | 08 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $46 | $156 | Not Implemented |
OK0770 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,297 | $0 | Implemented |
OK0770 # 02 Y:2008 | 02 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,597 | $0 | Implemented |
OK0770 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $669 | $1,056 | Implemented |
OK0770 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,014 | $5,534 | Not Implemented |
OK0770 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,686 | $17,885 | Implemented |
OK0770 # 06 Y:2008 | 06 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,894 | $1,346 | Not Implemented |
OK0770 # 07 Y:2008 | 07 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,527 | $0 | Implemented |
IC0149 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,460 | $9,635 | Implemented |
IC0149 # 02 Y:2008 | 02 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,168 | $18,015 | Not Implemented |
IC0149 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $1,470 | $7,381 | Implemented |
IC0149 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,526 | $2,040 | Implemented |
IC0149 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $141 | $0 | Implemented |
IC0149 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,594 | $1,610 | Implemented |
IC0149 # 07 Y:2008 | 07 | 2008 | UPGRADE OBSOLETE EQUIPMENT | $19,706 | $210 | Implemented |
IC0149 # 08 Y:2008 | 08 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $37,783 | $29,280 | Implemented |
IC0149 # 09 Y:2008 | 09 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $849 | $0 | Implemented |
IC0149 # 10 Y:2008 | 10 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,263 | $0 | Implemented |
IC0149 # 11 Y:2008 | 11 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,626 | $0 | Not Implemented |
GT0856 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,537 | $2,000 | Implemented |