Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
504
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0177 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,920 | $0 | Not Implemented |
AS0175 # 01 Y:1996 | 01 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $3,647 | $11,000 | Not Implemented |
AS0175 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,105 | $6,800 | Not Implemented |
AS0175 # 03 Y:1996 | 03 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,925 | $6,300 | Implemented |
AS0175 # 04 Y:1996 | 04 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $27,635 | $25,000 | Not Implemented |
AS0175 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $1,625 | $1,350 | Implemented |
AS0175 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,214 | $21,652 | Implemented |
AS0175 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $237 | $499 | Implemented |
AS0175 # 08 Y:1996 | 08 | 1996 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $8,910 | $1,200 | Not Implemented |
AS0170 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,371 | $2,769 | Implemented |
AS0170 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,404 | $0 | Implemented |
AS0170 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,702 | $0 | Implemented |
AS0170 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $3,744 | $1,050 | Not Implemented |
AS0170 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $476 | $810 | Implemented |
AS0170 # 06 Y:1996 | 06 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,591 | $8,540 | Not Implemented |
AS0170 # 07 Y:1996 | 07 | 1996 | MINIMIZE WATER USAGE | $404 | $1,455 | Implemented |
AS0167 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,627 | $3,381 | Implemented |
AS0167 # 02 Y:1996 | 02 | 1996 | INSULATE BARE EQUIPMENT | $145 | $137 | Implemented |
AS0167 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $938 | $0 | Implemented |
AS0167 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $596 | $560 | Not Implemented |
AS0167 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,634 | $10,934 | Implemented |
AS0167 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $577 | $975 | Implemented |
AS0167 # 07 Y:1996 | 07 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,000 | $19,750 | Implemented |
AS0152 # 01 Y:1995 | 01 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $840 | $250 | Not Implemented |
AS0152 # 02 Y:1995 | 02 | 1995 | REDUCE HEAT GAIN BY WINDOW TINTING | $5,891 | $6,750 | Not Implemented |