Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
753
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0166 # 04 Y:1999 | 04 | 1999 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $1,395 | $3,000 | Not Implemented |
SD0215 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,652 | $3,480 | Not Implemented |
SD0215 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,635 | $6,257 | Implemented |
SD0215 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $1,080 | $906 | Not Implemented |
SD0215 # 04 Y:1999 | 04 | 1999 | REDUCE VENTILATION AIR | $2,763 | $1,600 | Not Implemented |
SD0215 # 05 Y:1999 | 05 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $1,153 | $3,000 | Not Implemented |
SD0215 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,300 | $7,000 | Not Implemented |
SD0215 # 07 Y:1999 | 07 | 1999 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $13,012 | $0 | Not Implemented |
SD0215 # 08 Y:1999 | 08 | 1999 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $507,180 | $5,000 | Not Implemented |
SF0161 # 01 Y:1999 | 01 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $834 | $389 | Not Implemented |
SF0161 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,859 | $1,055 | Not Implemented |
SF0161 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,053 | $1,408 | Not Implemented |
SF0161 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,081 | $8,340 | Not Implemented |
SD0214 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,221 | $5,880 | Not Implemented |
SD0214 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,699 | $10,196 | Implemented |
SD0214 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,874 | $1,100 | Not Implemented |
SD0214 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $38,175 | $12,000 | Not Implemented |
SD0214 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $800 | $0 | Implemented |
SD0214 # 06 Y:1999 | 06 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,832 | $1,000 | Implemented |
SD0214 # 07 Y:1999 | 07 | 1999 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $3,600 | $2,300 | Implemented |
SD0214 # 08 Y:1999 | 08 | 1999 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $86,788 | $60,000 | Not Implemented |
SD0210 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $901 | $0 | Not Implemented |
SD0210 # 02 Y:1998 | 02 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,500 | $36,250 | Not Implemented |
SD0210 # 03 Y:1998 | 03 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $8,860 | $3,100 | Not Implemented |
SF0149 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $690 | $15 | Implemented |