Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

504

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0116 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $33,572 $18,827 Implemented
AS0116 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $981 $0 Not Implemented
AS0116 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $6,773 $8,970 Not Implemented
AS0116 # 06 Y:1994 06 1994 INSULATE BARE EQUIPMENT $7,749 $3,050 Not Implemented
AS0116 # 07 Y:1994 07 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $45,284 $83,400 Implemented
AS0111 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,872 $25,010 n/a
AS0111 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $2,286 $1,153 n/a
AS0111 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $207 $340 n/a
AS0111 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,395 $2,054 n/a
AS0111 # 05 Y:1994 05 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $626 $3,044 n/a
AS0111 # 06 Y:1994 06 1994 USE CASCADE SYSTEM OF RECIRCULATING DURING COLD WEATHER TO AVOID SUB-COOLING $4,008 $12,000 n/a
AS0111 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $749 $500 n/a
AS0111 # 08 Y:1994 08 1994 USE SYNTHETIC LUBRICANT $1,758 $2,330 n/a
AS0111 # 09 Y:1994 09 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,932 $2,000 n/a
AS0108 # 01 Y:1994 01 1994 INSTALL OCCUPANCY SENSORS $1,756 $825 Not Implemented
AS0108 # 02 Y:1994 02 1994 USE SYNTHETIC LUBRICANT $2,004 $1,342 Not Implemented
AS0108 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $546 $500 Implemented
AS0108 # 04 Y:1994 04 1994 INSTALL TIMERS AND/OR THERMOSTATS $2,997 $585 Not Implemented
AS0108 # 05 Y:1994 05 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,611 $26,535 Not Implemented
AS0108 # 06 Y:1994 06 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $374 $2,060 Not Implemented
AS0096 # 01 Y:1993 01 1993 ADD AREA LIGHTING SWITCHES $1,219 $2,012 Implemented
AS0096 # 02 Y:1993 02 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,441 $0 Implemented
AS0096 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $369 $497 Not Implemented
AS0096 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $628 $0 Not Implemented
AS0096 # 05 Y:1993 05 1993 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $4,006 $7,200 Implemented