Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
427
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0271 # 07 Y:1996 | 07 | 1996 | CONVERT TO ELECTROSTATIC POWDER COATING | $52,440 | $160,000 | Implemented |
KG0018 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,874 | $699 | Not Implemented |
KG0018 # 02 Y:1995 | 02 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,356 | $450 | Not Implemented |
KG0018 # 03 Y:1995 | 03 | 1995 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $370 | $0 | Not Implemented |
KG0018 # 04 Y:1995 | 04 | 1995 | INSTALL OCCUPANCY SENSORS | $307 | $195 | Not Implemented |
KG0018 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $89 | $15 | Not Implemented |
KG0003 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,276 | $9,920 | Implemented |
KG0003 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,639 | $2,314 | Not Implemented |
KG0003 # 03 Y:1994 | 03 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,257 | $2,200 | Implemented |
KG0003 # 04 Y:1994 | 04 | 1994 | INSULATE BARE EQUIPMENT | $1,863 | $100 | Not Implemented |
KG0003 # 05 Y:1994 | 05 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,629 | $2,500 | Implemented |
KG0003 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $126 | $155 | Not Implemented |
KG0003 # 07 Y:1994 | 07 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $372 | $1,186 | Implemented |
AM0098 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $51,060 | $175,500 | Not Implemented |
AM0098 # 02 Y:1990 | 02 | 1990 | OPTIMIZE PLANT POWER FACTOR | $20,490 | $34,000 | Implemented |
AM0098 # 03 Y:1990 | 03 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,980 | $900 | Implemented |
AM0098 # 04 Y:1990 | 04 | 1990 | INSULATE BARE EQUIPMENT | $3,100 | $115 | Implemented |
AM0098 # 05 Y:1990 | 05 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,850 | $11,750 | Not Implemented |
AM0098 # 06 Y:1990 | 06 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,330 | $10,500 | Not Implemented |
AM0098 # 07 Y:1990 | 07 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $1,980 | $7,700 | Implemented |
AM0098 # 08 Y:1990 | 08 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $970 | $137 | Implemented |
AM0098 # 09 Y:1990 | 09 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $695 | $700 | Implemented |
AM0098 # 10 Y:1990 | 10 | 1990 | INSTALL SET-BACK TIMERS | $500 | $1,180 | Not Implemented |
AM0098 # 11 Y:1990 | 11 | 1990 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $106 | $0 | Implemented |
AM0089 # 01 Y:1990 | 01 | 1990 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,920 | $4,700 | Not Implemented |