Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
263
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0916 # 04 Y:2018 | 04 | 2018 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $55,747 | $3,800 | Implemented |
GT0916 # 03 Y:2018 | 03 | 2018 | USE OPTIMUM TEMPERATURE | $29,211 | $1,600 | Not Implemented |
GT0916 # 02 Y:2018 | 02 | 2018 | AIR CONDITION ONLY SPACE NECESSARY | $5,518 | $200 | Not Implemented |
GT0916 # 01 Y:2018 | 01 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,228 | $263 | Implemented |
GT0895 # 07 Y:2017 | 07 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,216 | $6,000 | Not Implemented |
GT0895 # 06 Y:2017 | 06 | 2017 | INSTALL TIMERS AND/OR THERMOSTATS | $5,005 | $5,200 | Not Implemented |
GT0895 # 05 Y:2017 | 05 | 2017 | USE SOLAR HEAT TO MAKE ELECTRICTY | $110,000 | $429,000 | Not Implemented |
GT0895 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68,229 | $85,688 | Implemented |
GT0895 # 03 Y:2017 | 03 | 2017 | INSTALL TIMERS AND/OR THERMOSTATS | $4,720 | $11,140 | Implemented |
GT0895 # 02 Y:2017 | 02 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,819 | $4,560 | Not Implemented |
GT0895 # 01 Y:2017 | 01 | 2017 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $35,273 | $4,360 | Not Implemented |
GT0879 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,458 | $56,350 | Not Implemented |
GT0879 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,235 | $1 | Not Implemented |
GT0879 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $3,260 | $4,050 | Not Implemented |
GT0879 # 05 Y:2011 | 05 | 2011 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $4,339 | $8,740 | Not Implemented |
GT0879 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45,254 | $2,500 | Implemented |
GT0879 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $339,042 | $1,340,000 | Not Implemented |
GT0856 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,290 | $2,000 | Implemented |
GT0856 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,537 | $2,000 | Implemented |
GT0856 # 03 Y:2008 | 03 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $8,620 | $3,000 | Not Implemented |
GT0856 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,097 | $4,500 | Implemented |
GT0856 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,329 | $80,207 | Implemented |
GT0856 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,723 | $0 | Implemented |
GT0856 # 06 Y:2008 | 06 | 2008 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $8,400 | $15,000 | Not Implemented |
GT0856 # 07 Y:2008 | 07 | 2008 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,385 | $13,000 | Not Implemented |