Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 361 | Electric Distribution Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0400 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $75 | $200 | Implemented |
NC0400 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $1,761 | $4,346 | Implemented |
NC0400 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,571 | $11,072 | Not Implemented |
NC0400 # 02 Y:2010 | 02 | 2010 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $9,007 | $37,000 | Implemented |
NC0400 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,103 | $60,000 | Not Implemented |
NC0378 # 02 Y:2008 | 02 | 2008 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $56,045 | $85,000 | Not Implemented |
NC0378 # 11 Y:2008 | 11 | 2008 | USE PHOTOCELL CONTROLS | $3,452 | $12,000 | Implemented |
NC0378 # 10 Y:2008 | 10 | 2008 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $32,100 | $100,000 | Not Implemented |
NC0378 # 08 Y:2008 | 08 | 2008 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $226,587 | $37,500 | Implemented |
NC0378 # 07 Y:2008 | 07 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,481 | $100 | Implemented |
NC0378 # 06 Y:2008 | 06 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,591 | $7,700 | Implemented |
NC0378 # 05 Y:2008 | 05 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,355 | $7,450 | Not Implemented |
NC0378 # 04 Y:2008 | 04 | 2008 | REVISE SMOKE CLEANUP FROM OPERATIONS | $2,215 | $7,700 | Not Implemented |
NC0378 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,480 | $500 | Not Implemented |
NC0378 # 01 Y:2008 | 01 | 2008 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $97,991 | $50,000 | Implemented |
NC0378 # 09 Y:2008 | 09 | 2008 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $10,000 | $1,000 | Implemented |
TN0687 # 10 Y:2000 | 10 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $720 | $0 | Implemented |
TN0687 # 09 Y:2000 | 09 | 2000 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $893 | $2,950 | Not Implemented |
TN0687 # 08 Y:2000 | 08 | 2000 | INSULATE BARE EQUIPMENT | $1,562 | $188 | Not Implemented |
TN0687 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,680 | $350 | Implemented |
TN0687 # 06 Y:2000 | 06 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $2,289 | $2,150 | Implemented |
TN0687 # 05 Y:2000 | 05 | 2000 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $3,280 | $2,925 | Not Implemented |
TN0687 # 04 Y:2000 | 04 | 2000 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $4,210 | $820 | Implemented |
TN0687 # 03 Y:2000 | 03 | 2000 | TREAT AND REUSE RINSE WATERS | $6,496 | $14,340 | Not Implemented |
TN0687 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,703 | $750 | Implemented |