Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
739
matching recommendationsSIC | 361 | Electric Distribution Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0410 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $4,311 | $122 | Not Implemented |
UF0410 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $136,962 | $129,516 | Not Implemented |
UF0410 # 08 Y:2008 | 08 | 2008 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,174 | $2,995 | Not Implemented |
WV0369 # 01 Y:2008 | 01 | 2008 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $108,677 | $0 | Implemented |
WV0369 # 02 Y:2008 | 02 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $77,536 | $198,000 | Not Implemented |
WV0369 # 03 Y:2008 | 03 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $48,102 | $41,400 | Implemented |
WV0369 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,982 | $71,794 | Implemented |
WV0369 # 05 Y:2008 | 05 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,912 | $8,070 | Not Implemented |
WV0369 # 06 Y:2008 | 06 | 2008 | OPTIMIZE PLANT POWER FACTOR | $7,680 | $24,500 | Implemented |
WV0369 # 07 Y:2008 | 07 | 2008 | ISOLATE HOT OR COLD EQUIPMENT | $5,682 | $952 | Implemented |
WV0369 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,504 | $2,520 | Not Implemented |
WV0369 # 09 Y:2008 | 09 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,365 | $11,160 | Not Implemented |
WV0369 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,950 | $0 | Implemented |
WV0369 # 11 Y:2008 | 11 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $2,687 | $1,000 | Implemented |
WV0369 # 12 Y:2008 | 12 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,264 | $2,000 | Implemented |
WV0369 # 13 Y:2008 | 13 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $2,047 | $776 | Implemented |
WV0369 # 14 Y:2008 | 14 | 2008 | INSULATE BARE EQUIPMENT | $2,008 | $1,241 | Implemented |
WV0369 # 15 Y:2008 | 15 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,004 | $87 | Not Implemented |
WV0369 # 16 Y:2008 | 16 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,266 | $114 | Implemented |
WV0369 # 17 Y:2008 | 17 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $835 | $0 | Implemented |
WV0369 # 18 Y:2008 | 18 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $819 | $1,484 | Not Implemented |
WV0369 # 19 Y:2008 | 19 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $563 | $585 | Implemented |
WV0369 # 20 Y:2008 | 20 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $389 | $470 | Implemented |
MZ0018 # 01 Y:2007 | 01 | 2007 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $25,600 | $0 | Not Implemented |
MZ0018 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,872 | $0 | Not Implemented |