Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

551

matching recommendations
Reset
SIC 362 Electrical Industrial Apparatus
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0141 # 07 Y:1989 07 1989 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $1,906 $0 Implemented
AM0048 # 01 Y:1989 01 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,794 $19,916 Implemented
AM0048 # 03 Y:1989 03 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,025 $700 Implemented
AM0048 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,274 $0 Implemented
AM0048 # 07 Y:1989 07 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $65 $57 Implemented
GT0360 # 01 Y:1988 01 1988 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,520 $0 Implemented
GT0360 # 02 Y:1988 02 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,950 $1,800 Implemented
GT0360 # 04 Y:1988 04 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,741 $21,965 Implemented
GT0360 # 06 Y:1988 06 1988 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $490 $500 Implemented
OK0268 # 02 Y:1988 02 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,034 $520 Implemented
OK0268 # 03 Y:1988 03 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,336 $0 Implemented
OK0268 # 05 Y:1988 05 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $11,350 $2,030 Implemented
OK0268 # 06 Y:1988 06 1988 INSULATE BARE EQUIPMENT $2,083 $1,185 Implemented
OK0268 # 07 Y:1988 07 1988 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $320 $637 Implemented
OK0268 # 08 Y:1988 08 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,742 $275 Implemented
AT0110 # 01 Y:1988 01 1988 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $18,131 $5,540 Implemented
AT0110 # 02 Y:1988 02 1988 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $25,785 $5,000 Implemented
AT0110 # 03 Y:1988 03 1988 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $2,765 $3,500 Implemented
AT0110 # 05 Y:1988 05 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $21,453 $21,000 Implemented
AT0110 # 07 Y:1988 07 1988 RECOVER WASTE HEAT FROM EQUIPMENT $32,558 $5,000 Implemented
AT0110 # 08 Y:1988 08 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $378 $331 Implemented
AT0110 # 09 Y:1988 09 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $705 $1,500 Implemented
AT0110 # 11 Y:1988 11 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $622 $0 Implemented
WI0013 # 02 Y:1987 02 1987 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $302 $0 Implemented
WI0013 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,253 $4,328 Implemented