Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,337
matching recommendationsSIC | 362 | Electrical Industrial Apparatus |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0534 # 06 Y:2007 | 06 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,370 | $0 | Implemented |
AM0534 # 07 Y:2007 | 07 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,150 | $0 | Not Implemented |
AM0534 # 08 Y:2007 | 08 | 2007 | USE SYNTHETIC LUBRICANT | $320 | $0 | Implemented |
CO0608 # 01 Y:2007 | 01 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $11,650 | $56,600 | Implemented |
CO0608 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,530 | $1,500 | Implemented |
CO0608 # 03 Y:2007 | 03 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,470 | $60 | Implemented |
CO0608 # 04 Y:2007 | 04 | 2007 | REPLACE BOILER | $23,660 | $20,000 | Implemented |
CO0608 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $340 | $1,370 | Implemented |
WV0361 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $115,865 | $26,750 | Not Implemented |
WV0361 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $42,691 | $13,780 | Implemented |
WV0361 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $13,999 | $13,900 | Not Implemented |
WV0361 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,204 | $2,000 | Implemented |
WV0361 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,012 | $15,100 | Not Implemented |
WV0361 # 06 Y:2007 | 06 | 2007 | USE PHOTOCELL CONTROLS | $1,311 | $430 | Implemented |
WV0361 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $0 | Implemented |
WV0361 # 08 Y:2007 | 08 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $657 | $276 | Implemented |
OK0736 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $224,746 | $154,440 | Implemented |
OK0736 # 02 Y:2006 | 02 | 2006 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $447,023 | $299,500 | Not Implemented |
OK0736 # 03 Y:2006 | 03 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $29,250 | $20,340 | Implemented |
OK0736 # 04 Y:2006 | 04 | 2006 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $8,438 | $765 | Implemented |
OK0736 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,322 | $1,267 | Implemented |
OK0736 # 06 Y:2006 | 06 | 2006 | USE PHOTOCELL CONTROLS | $3,268 | $225 | Not Implemented |
WV0343 # 01 Y:2006 | 01 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,166,408 | $1,460,000 | Not Implemented |
WV0343 # 02 Y:2006 | 02 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,096,704 | $1,539,100 | Not Implemented |
WV0343 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $21,955 | $3,114 | Implemented |