Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
65
matching recommendationsSIC | 362 | Electrical Industrial Apparatus |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0180 # 01 Y:1999 | 01 | 1999 | USE SYNTHETIC LUBRICANT | $1,188 | $867 | Implemented |
WV0180 # 12 Y:1999 | 12 | 1999 | INSTALL SYSTEM TO COLLECT SCRAP | $8,308 | $500 | Implemented |
WV0180 # 11 Y:1999 | 11 | 1999 | USE EVAPORATION TO CONCENTRATE MATERIAL | $1,107 | $50 | Not Implemented |
WV0180 # 10 Y:1999 | 10 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $750 | $250 | Not Implemented |
WV0180 # 06 Y:1999 | 06 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,447 | $27 | Not Implemented |
WV0180 # 05 Y:1999 | 05 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,780 | $3,000 | Implemented |
WV0180 # 04 Y:1999 | 04 | 1999 | USE OPTIMUM THICKNESS INSULATION | $2,992 | $1,125 | Not Implemented |
WV0180 # 09 Y:1999 | 09 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $550 | $201 | Implemented |
WV0180 # 08 Y:1999 | 08 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $370 | $90 | Not Implemented |
WV0180 # 07 Y:1999 | 07 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $71,180 | $39,000 | Not Implemented |
WV0180 # 02 Y:1999 | 02 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $30 | $0 | Implemented |
WV0180 # 03 Y:1999 | 03 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $87 | $423 | Not Implemented |
WI0354 # 10 Y:1999 | 10 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $373 | $640 | Implemented |
WI0354 # 03 Y:1999 | 03 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $5,465 | $0 | Implemented |
WI0354 # 07 Y:1999 | 07 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $1,418 | $4,850 | Not Implemented |
WI0354 # 09 Y:1999 | 09 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $477 | $180 | Implemented |
WI0354 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,567 | $18,988 | Implemented |
WI0354 # 11 Y:1999 | 11 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $360 | $800 | Implemented |
WI0354 # 06 Y:1999 | 06 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $2,328 | $400 | Implemented |
WI0354 # 08 Y:1999 | 08 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,284 | $5,000 | Implemented |
WI0354 # 05 Y:1999 | 05 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $2,618 | $500 | Not Implemented |
WI0354 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,469 | $500 | Implemented |
WI0354 # 01 Y:1999 | 01 | 1999 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $7,740 | $21,000 | Not Implemented |
OD0139 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,834 | $61,640 | Not Implemented |
OD0139 # 02 Y:1999 | 02 | 1999 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $447 | $4,020 | Not Implemented |