Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

580

matching recommendations
Reset
SIC 3621 Motors And Generators
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0261 # 10 Y:1999 10 1999 MINIMIZE WATER USAGE $788 $500 Implemented
ME0261 # 11 Y:1999 11 1999 DEVELOP A REPAIR/REPLACE POLICY $271 $325 Implemented
ME0261 # 12 Y:1999 12 1999 $29 $27 Implemented
UD0562 # 01 Y:1999 01 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $14,767 $10,000 Not Implemented
UD0562 # 02 Y:1999 02 1999 USE POWER DURING OFF-PEAK PERIODS $10,130 $0 Implemented
UD0562 # 03 Y:1999 03 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $4,200 $4,000 Not Implemented
UD0562 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,677 $1,040 Implemented
UD0562 # 05 Y:1999 05 1999 FILTER AND REUSE HYDRAULIC OIL $5,340 $4,000 Not Implemented
UD0562 # 06 Y:1999 06 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,976 $13,500 Not Implemented
UD0562 # 07 Y:1999 07 1999 RECYCLE CLEANING SOLVENT AND REUSE $2,344 $4,000 Not Implemented
UD0562 # 08 Y:1999 08 1999 REPROCESS SPENT OILS ON SITE FOR RE-USE $2,041 $3,000 Not Implemented
UL0209 # 01 Y:1998 01 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,561 $2,000 Not Implemented
UL0209 # 02 Y:1998 02 1998 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $4,743 $0 Not Implemented
UL0209 # 03 Y:1998 03 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,173 $0 Implemented
UL0209 # 04 Y:1998 04 1998 REUSE / RECYCLE/ SELL PAPER PRODUCTS $2,442 $0 Not Implemented
UL0209 # 05 Y:1998 05 1998 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $4,330 $78 Implemented
MS0107 # 01 Y:1998 01 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,339 $2,000 Implemented
MS0107 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,380 $718 Not Implemented
MS0107 # 03 Y:1998 03 1998 INSTALL TIMERS AND/OR THERMOSTATS $1,719 $3,248 Implemented
MS0107 # 04 Y:1998 04 1998 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $96,541 $13,936 Implemented
MS0107 # 05 Y:1998 05 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,757 $20,202 Implemented
MS0107 # 06 Y:1998 06 1998 INSTALL OCCUPANCY SENSORS $3,239 $761 Not Implemented
MS0107 # 07 Y:1998 07 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $12,237 $0 Implemented
MS0107 # 08 Y:1998 08 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $1,327 $1,690 Not Implemented
MS0107 # 09 Y:1998 09 1998 CONDENSE OPERATION INTO ONE BUILDING $187,809 $34,932 Implemented