Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

580

matching recommendations
Reset
SIC 3621 Motors And Generators
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MO0090 # 08 Y:1993 08 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $13,876 $3,216 Not Implemented
MO0075 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $328 $6,500 Not Implemented
MO0075 # 02 Y:1992 02 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $948 $370 Not Implemented
MO0075 # 03 Y:1992 03 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $643 $150 Implemented
MO0075 # 04 Y:1992 04 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $312 $670 Not Implemented
MO0075 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $677 $5,000 Not Implemented
MO0075 # 06 Y:1992 06 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $764 $332 Not Implemented
MO0075 # 07 Y:1992 07 1992 RECOVER AND REUSE COOLING WATER $1,493 $0 Not Implemented
UD0378 # 01 Y:1992 01 1992 INSTALL SET-BACK TIMERS $23,156 $0 Not Implemented
UD0378 # 02 Y:1992 02 1992 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,650 $0 Not Implemented
UD0378 # 03 Y:1992 03 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,357 $0 Not Implemented
UD0378 # 04 Y:1992 04 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $13,114 $14,400 Implemented
SD0025 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $130 $900 Implemented
SD0025 # 02 Y:1992 02 1992 TURN OFF EQUIPMENT WHEN NOT IN USE $710 $120 Implemented
SD0025 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,866 $2,000 Implemented
SD0025 # 04 Y:1992 04 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $582 $45 Not Implemented
SD0025 # 05 Y:1992 05 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,093 $4,450 Implemented
SD0025 # 06 Y:1992 06 1992 INSULATE BARE EQUIPMENT $338 $77 Not Implemented
SD0025 # 07 Y:1992 07 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $785 $925 Not Implemented
SD0025 # 08 Y:1992 08 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,781 $1,200 Not Implemented
SD0025 # 09 Y:1992 09 1992 INSTALL SET-BACK TIMERS $2,785 $3,240 Not Implemented
SD0025 # 10 Y:1992 10 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,471 $1,980 Not Implemented
SD0009 # 01 Y:1991 01 1991 ISOLATE HOT OR COLD EQUIPMENT $614 $690 Not Implemented
SD0009 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $293 $100 Not Implemented
SD0009 # 03 Y:1991 03 1991 KEEP LAMPS AND REFLECTORS CLEAN $4,323 $8,400 Not Implemented