Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsSIC | 3621 | Motors And Generators |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0770 # 07 Y:2008 | 07 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,527 | $0 | Implemented |
OK0770 # 06 Y:2008 | 06 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,894 | $1,346 | Not Implemented |
OK0770 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,686 | $17,885 | Implemented |
OK0770 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,014 | $5,534 | Not Implemented |
OK0770 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $669 | $1,056 | Implemented |
OK0770 # 02 Y:2008 | 02 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,597 | $0 | Implemented |
OK0770 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,297 | $0 | Implemented |
AR0125 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,053 | $1,212 | Not Implemented |
AR0125 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,085 | $186 | Implemented |
AR0125 # 03 Y:1997 | 03 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $200 | $229 | Not Implemented |
AR0125 # 04 Y:1997 | 04 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $265 | $0 | Not Implemented |
AR0125 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,152 | $150 | Implemented |
AR0125 # 06 Y:1997 | 06 | 1997 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $89 | $0 | Not Implemented |
AR0125 # 07 Y:1997 | 07 | 1997 | RECOVER AND REUSE COOLING WATER | $6,309 | $8,400 | Implemented |
AR0125 # 08 Y:1997 | 08 | 1997 | RECOVER AND REUSE COOLING WATER | $4,837 | $31,000 | Implemented |
AR0125 # 09 Y:1997 | 09 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $31,334 | $2,000 | Implemented |
AR0125 # 10 Y:1997 | 10 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $4,700 | $1,000 | Not Implemented |
AR0108 # 10 Y:1997 | 10 | 1997 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $113,100 | $30,000 | Implemented |
AR0108 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $2,070 | $1,000 | Not Implemented |
AR0108 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,303 | $415 | Implemented |
AR0108 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $560 | $186 | Implemented |
AR0108 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $622 | $270 | Implemented |
AR0108 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $469 | $1,050 | Implemented |
AR0108 # 05 Y:1997 | 05 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $274 | $0 | Implemented |
AR0108 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,231 | $100 | Implemented |