Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
113
matching recommendationsSIC | 364 | Electric Lighting And Wiring Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0027 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,486 | $1,250 | Not Implemented |
BD0027 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,966 | $5,865 | Not Implemented |
BD0027 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $826 | $250 | Not Implemented |
BD0027 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,398 | $4,780 | Not Implemented |
BD0027 # 07 Y:1995 | 07 | 1995 | CONVERT TO ELECTROSTATIC POWDER COATING | $35,328 | $3,000 | Not Implemented |
WI0214 # 01 Y:1994 | 01 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $30,762 | $31,200 | Not Implemented |
WI0214 # 02 Y:1994 | 02 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $10,026 | $15,000 | Not Implemented |
WI0214 # 03 Y:1994 | 03 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,933 | $600 | Implemented |
WI0214 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,450 | $350 | Implemented |
WI0214 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $2,036 | Implemented |
WI0214 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $323 | $0 | Not Implemented |
WI0214 # 07 Y:1994 | 07 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,682 | $500 | Implemented |
WI0214 # 08 Y:1994 | 08 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,097 | $1,600 | Not Implemented |
WI0214 # 09 Y:1994 | 09 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,642 | $640 | Implemented |
WI0214 # 10 Y:1994 | 10 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $384 | $700 | Not Implemented |
WI0214 # 11 Y:1994 | 11 | 1994 | ELIMINATE/REDUCE AN OPERATION | $7,500 | $0 | Not Implemented |
WI0214 # 12 Y:1994 | 12 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,650 | $2,500 | Not Implemented |
WI0154 # 01 Y:1992 | 01 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $33,712 | $160,000 | n/a |
WI0154 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $6,762 | $1,000 | n/a |
WI0154 # 03 Y:1992 | 03 | 1992 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,277 | $0 | n/a |
WI0154 # 04 Y:1992 | 04 | 1992 | AIR CONDITION ONLY SPACE NECESSARY | $5,948 | $0 | n/a |
WI0154 # 05 Y:1992 | 05 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,359 | $7,700 | n/a |
WI0154 # 06 Y:1992 | 06 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,257 | $10,000 | n/a |
WI0154 # 07 Y:1992 | 07 | 1992 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $4,040 | $1,000 | n/a |
WI0154 # 08 Y:1992 | 08 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $356 | $1,280 | n/a |