Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
56
matching recommendationsSIC | 364 | Electric Lighting And Wiring Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0319 # 06 Y:1994 | 06 | 1994 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,125 | $2,197 | Not Implemented |
MA0319 # 05 Y:1994 | 05 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $919 | $3,119 | Not Implemented |
MA0319 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,463 | $10,240 | Not Implemented |
MA0319 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,357 | $12,000 | Implemented |
MA0319 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,412 | $10,920 | Not Implemented |
MA0319 # 04 Y:1994 | 04 | 1994 | USE SYNTHETIC LUBRICANT | $2,218 | $555 | Not Implemented |
SF0040 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,261 | $600 | Implemented |
SF0040 # 05 Y:1994 | 05 | 1994 | USE SYNTHETIC LUBRICANT | $444 | $0 | Implemented |
SF0040 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $811 | $1,150 | Implemented |
SF0040 # 04 Y:1994 | 04 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $409 | $1,013 | Implemented |
SF0040 # 02 Y:1994 | 02 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,250 | $0 | Implemented |
SF0040 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $973 | $1,785 | Implemented |
WI0214 # 08 Y:1994 | 08 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,097 | $1,600 | Not Implemented |
WI0214 # 09 Y:1994 | 09 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,642 | $640 | Implemented |
WI0214 # 01 Y:1994 | 01 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $30,762 | $31,200 | Not Implemented |
WI0214 # 02 Y:1994 | 02 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $10,026 | $15,000 | Not Implemented |
WI0214 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,450 | $350 | Implemented |
WI0214 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $323 | $0 | Not Implemented |
WI0214 # 03 Y:1994 | 03 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,933 | $600 | Implemented |
WI0214 # 07 Y:1994 | 07 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,682 | $500 | Implemented |
WI0214 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $2,036 | Implemented |
WI0214 # 10 Y:1994 | 10 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $384 | $700 | Not Implemented |
WI0214 # 11 Y:1994 | 11 | 1994 | ELIMINATE/REDUCE AN OPERATION | $7,500 | $0 | Not Implemented |
WI0214 # 12 Y:1994 | 12 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,650 | $2,500 | Not Implemented |
AR0025 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,343 | $9,530 | Implemented |