Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

426

matching recommendations
Reset
SIC 3643 Current-carrying Wiring Devices
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0638 # 12 Y:2002 12 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $128 $101 Implemented
NC0152 # 01 Y:1998 01 1998 RECOVER WASTE HEAT FROM EQUIPMENT $4,388 $1,000 Not Implemented
NC0152 # 02 Y:1998 02 1998 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $3,988 $13,000 Not Implemented
NC0152 # 03 Y:1998 03 1998 COVER OPEN TANKS $1,006 $100 Implemented
NC0152 # 04 Y:1998 04 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $396 $80 Not Implemented
NC0152 # 05 Y:1998 05 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,160 $0 Implemented
NC0152 # 06 Y:1998 06 1998 REPROCESS SPENT OILS ON SITE FOR RE-USE $3,010 $5,000 Not Implemented
NC0152 # 07 Y:1998 07 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $563 $200 Implemented
NC0152 # 08 Y:1998 08 1998 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $16,777 $4,000 Not Implemented
NC0152 # 09 Y:1998 09 1998 $31,250 $12,850 Not Implemented
NV0103 # 01 Y:1998 01 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $179 $137 Implemented
NV0103 # 02 Y:1998 02 1998 USE PHOTOCELL CONTROLS $550 $200 Implemented
NV0103 # 03 Y:1998 03 1998 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $912 $750 Implemented
NV0103 # 04 Y:1998 04 1998 $44,986 $9,960 Implemented
NV0103 # 05 Y:1998 05 1998 $22,940 $7,800 Implemented
NV0103 # 06 Y:1998 06 1998 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $33 $0 Not Implemented
MS0093 # 01 Y:1997 01 1997 USE SYNTHETIC LUBRICANT $95 $33 Implemented
MS0093 # 02 Y:1997 02 1997 RECOVER WASTE HEAT FROM EQUIPMENT $996 $522 Implemented
MS0093 # 03 Y:1997 03 1997 DISCONNECT BALLASTS $133 $44 Implemented
MS0093 # 04 Y:1997 04 1997 INSTALL TIMERS AND/OR THERMOSTATS $5,880 $588 Implemented
MS0093 # 05 Y:1997 05 1997 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,352 $1,785 Implemented
MS0093 # 06 Y:1997 06 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,392 $0 Not Implemented
SF0099 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,768 $13,765 Implemented
SF0099 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $404 $1,363 Implemented
SF0099 # 03 Y:1996 03 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $436 $432 Implemented