Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
95
matching recommendationsSIC | 3648 | Lighting Equipment, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0271 # 06 Y:1996 | 06 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $34,400 | $0 | Not Implemented |
AM0271 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $6,248 | $11,200 | Implemented |
AM0271 # 02 Y:1996 | 02 | 1996 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,147 | $0 | Implemented |
AM0271 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,170 | $210 | Implemented |
AM0271 # 04 Y:1996 | 04 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,860 | $0 | Implemented |
AM0271 # 05 Y:1996 | 05 | 1996 | PAY UTILITY BILLS ON TIME | $267 | $0 | Not Implemented |
AM0271 # 07 Y:1996 | 07 | 1996 | CONVERT TO ELECTROSTATIC POWDER COATING | $52,440 | $160,000 | Implemented |
WI0214 # 02 Y:1994 | 02 | 1994 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $10,026 | $15,000 | Not Implemented |
WI0214 # 01 Y:1994 | 01 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $30,762 | $31,200 | Not Implemented |
WI0214 # 03 Y:1994 | 03 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,933 | $600 | Implemented |
WI0214 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,450 | $350 | Implemented |
WI0214 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $2,036 | Implemented |
WI0214 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $323 | $0 | Not Implemented |
WI0214 # 07 Y:1994 | 07 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,682 | $500 | Implemented |
WI0214 # 08 Y:1994 | 08 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,097 | $1,600 | Not Implemented |
WI0214 # 09 Y:1994 | 09 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,642 | $640 | Implemented |
WI0214 # 10 Y:1994 | 10 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $384 | $700 | Not Implemented |
WI0214 # 11 Y:1994 | 11 | 1994 | ELIMINATE/REDUCE AN OPERATION | $7,500 | $0 | Not Implemented |
WI0214 # 12 Y:1994 | 12 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,650 | $2,500 | Not Implemented |
WV0022 # 07 Y:1994 | 07 | 1994 | INSULATE BARE EQUIPMENT | $6,078 | $1,416 | Not Implemented |
WV0022 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $151 | $0 | Not Implemented |
WV0022 # 05 Y:1994 | 05 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,596 | $1,125 | Implemented |
WV0022 # 04 Y:1994 | 04 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,183 | $5,000 | Implemented |
WV0022 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $973 | $12,836 | Not Implemented |
WV0022 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $294 | $9,520 | Implemented |