Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0939 # 05 Y:2020 | 05 | 2020 | INSTALL TIMERS AND/OR THERMOSTATS | $652 | $563 | Implemented |
GT0939 # 04 Y:2020 | 04 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,758 | $8,593 | Implemented |
GT0939 # 03 Y:2020 | 03 | 2020 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $165,933 | $33,069 | Not Implemented |
GT0939 # 02 Y:2020 | 02 | 2020 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $17,391 | $2,000 | Implemented |
GT0939 # 01 Y:2020 | 01 | 2020 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $10,466 | $500 | Not Implemented |
GT0711 # 08 Y:2001 | 08 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $510 | $225 | Not Implemented |
GT0711 # 07 Y:2001 | 07 | 2001 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $140 | $800 | Not Implemented |
GT0711 # 06 Y:2001 | 06 | 2001 | USE SYNTHETIC LUBRICANT | $75 | $0 | Not Implemented |
GT0711 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,495 | $2,000 | Not Implemented |
GT0711 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,025 | $3,725 | Not Implemented |
GT0711 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $845 | $1,450 | Implemented |
GT0711 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $310 | Not Implemented |
GT0711 # 05 Y:2001 | 05 | 2001 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $15 | $0 | Implemented |
GT0688 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,760 | $1,050 | Not Implemented |
GT0688 # 08 Y:2000 | 08 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,435 | $4,950 | Not Implemented |
GT0688 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $280 | $800 | Implemented |
GT0688 # 01 Y:2000 | 01 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,444 | $2,240 | Implemented |
GT0688 # 07 Y:2000 | 07 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,920 | $450 | Not Implemented |
GT0688 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,190 | $12,285 | Not Implemented |
GT0688 # 06 Y:2000 | 06 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $17,022 | $53,400 | Implemented |
GT0688 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,360 | $15,907 | Not Implemented |
GT0549 # 04 Y:1995 | 04 | 1995 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $19,500 | $24,000 | Implemented |
GT0549 # 07 Y:1995 | 07 | 1995 | USE POWER DURING OFF-PEAK PERIODS | $1,830 | $4,000 | Not Implemented |
GT0549 # 06 Y:1995 | 06 | 1995 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $18,200 | $168,000 | Implemented |
GT0549 # 02 Y:1995 | 02 | 1995 | DISCONNECT BALLASTS | $11,120 | $2,895 | Implemented |