Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,199

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0017 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $627 $1,550 Not Implemented
BD0017 # 04 Y:1995 04 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $119 $242 Not Implemented
BD0017 # 05 Y:1995 05 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $119 $400 Implemented
BD0017 # 06 Y:1995 06 1995 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $809 $475 Not Implemented
SD0099 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,306 $7,840 Implemented
SD0099 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $28,013 $50,500 Not Implemented
SD0099 # 03 Y:1994 03 1994 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $47,221 $10,000 Not Implemented
SD0099 # 04 Y:1994 04 1994 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS $58,207 $132,600 Not Implemented
CO0317 # 01 Y:1994 01 1994 USE TIGHT-FITTING LIDS ON MATERIAL CONTAINERS TO REDUCE VOC EMISSIONS $6,860 $720 Not Implemented
CO0317 # 02 Y:1994 02 1994 DISTILL CONTAMINATED SOLVENTS FOR REUSE $3,603 $7,080 Not Implemented
CO0317 # 03 Y:1994 03 1994 INSULATE BARE EQUIPMENT $1,790 $520 Not Implemented
CO0317 # 04 Y:1994 04 1994 INSTALL TIMERS AND/OR THERMOSTATS $1,600 $150 Implemented
CO0317 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,270 $2,070 Implemented
CO0317 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $880 $1,340 Implemented
CO0317 # 07 Y:1994 07 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $700 $300 Implemented
CO0317 # 08 Y:1994 08 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $460 $150 Not Implemented
CO0317 # 09 Y:1994 09 1994 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $0 $140 Implemented
OR0218 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,336 $2,262 Implemented
OR0218 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $503 $4,100 Not Implemented
OR0218 # 03 Y:1994 03 1994 OPTIMIZE PLANT POWER FACTOR $7,770 $10,000 Implemented
OR0218 # 04 Y:1994 04 1994 HEAT WATER WITH EXHAUST HEAT $4,938 $8,847 Implemented
OR0218 # 05 Y:1994 05 1994 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $28,438 $35,000 Implemented
OR0218 # 06 Y:1994 06 1994 USE EVAPORATION TO CONCENTRATE MATERIAL $7,560 $38,847 Not Implemented
CO0315 # 01 Y:1994 01 1994 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $7,950 $30 Implemented
CO0315 # 02 Y:1994 02 1994 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $1,290 $0 Not Implemented