Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

154

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0695 # 11 Y:2004 11 2004 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $784 $0 Implemented
UD0695 # 12 Y:2004 12 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $729 $0 Implemented
UD0695 # 13 Y:2004 13 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $397 $756 Implemented
UD0695 # 14 Y:2004 14 2004 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $420 $340 Not Implemented
UD0695 # 15 Y:2004 15 2004 AIR CONDITION ONLY SPACE NECESSARY $339 $0 Implemented
UD0695 # 16 Y:2004 16 2004 DISCONNECT BALLASTS $327 $7 Implemented
UD0695 # 17 Y:2004 17 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $237 $213 Implemented
WV0254 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,829 $420 Not Implemented
WV0254 # 02 Y:2002 02 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,033 $120 Implemented
WV0254 # 03 Y:2002 03 2002 RECOVER WASTE HEAT FROM EQUIPMENT $7,900 $460 Not Implemented
WV0254 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $14,421 $1,200 Not Implemented
WV0254 # 05 Y:2002 05 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,172 $200 Implemented
WV0254 # 06 Y:2002 06 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $755 $600 Implemented
WV0254 # 07 Y:2002 07 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,833 $1,000 Implemented
WV0254 # 08 Y:2002 08 2002 INSULATE BARE EQUIPMENT $1,756 $483 Implemented
WV0254 # 09 Y:2002 09 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,809 $600 Implemented
WV0254 # 10 Y:2002 10 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,987 $300 Implemented
WV0254 # 11 Y:2002 11 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,240 $0 Implemented
WV0254 # 12 Y:2002 12 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,039 $3,154 Implemented
WV0254 # 13 Y:2002 13 2002 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $7,844 $4,000 Not Implemented
WV0254 # 14 Y:2002 14 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,200 $100 Implemented
WV0254 # 15 Y:2002 15 2002 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $14,000 $6,000 Not Implemented
UD0624 # 01 Y:2001 01 2001 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $29,813 $10,710 Not Implemented
UD0624 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,975 $13,704 Implemented
UD0624 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $980 $414 Implemented