Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
373
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0299 # 01 Y:2001 | 01 | 2001 | INSTALL SKYLIGHTS | $1,721 | $2,490 | Not Implemented |
AS0299 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,205 | $5,889 | Not Implemented |
AS0299 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $329 | $675 | Not Implemented |
AS0299 # 04 Y:2001 | 04 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,440 | $60 | Not Implemented |
AS0299 # 05 Y:2001 | 05 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $288 | $60 | Not Implemented |
AS0295 # 05 Y:2001 | 05 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $152 | $60 | Not Implemented |
AS0295 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,104 | $5,107 | Not Implemented |
AS0295 # 02 Y:2001 | 02 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,459 | $10,800 | Not Implemented |
AS0295 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $433 | $450 | Not Implemented |
AS0295 # 04 Y:2001 | 04 | 2001 | USE SYNTHETIC LUBRICANT | $826 | $694 | Not Implemented |
AS0295 # 06 Y:2001 | 06 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $234,131 | $140,869 | Implemented |
AS0286 # 08 Y:2000 | 08 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,509 | $780 | Not Implemented |
AS0286 # 07 Y:2000 | 07 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $576 | $60 | Not Implemented |
AS0286 # 06 Y:2000 | 06 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,244 | $120 | Not Implemented |
AS0286 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,262 | $120 | Not Implemented |
AS0286 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $407 | $609 | Not Implemented |
AS0286 # 09 Y:2000 | 09 | 2000 | AUTOMATE FINISHING PROCESS | $5,355 | $1,500 | Not Implemented |
AS0286 # 10 Y:2000 | 10 | 2000 | MODIFY STARTUP/SHUTDOWN TIMES | $567 | $120 | Not Implemented |
AS0286 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,073 | $6,959 | Not Implemented |
AS0286 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,469 | $3,800 | Not Implemented |
AS0286 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,045 | $382 | Not Implemented |
AS0274 # 11 Y:2000 | 11 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $54,284 | $180,000 | Not Implemented |
AS0274 # 12 Y:2000 | 12 | 2000 | APPLY FOR INVESTMENT INCENTIVES | $1,580 | $60 | Not Implemented |
AS0274 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,779 | $15,136 | Implemented |
AS0274 # 02 Y:2000 | 02 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,019 | $14,000 | Implemented |