Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
154
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0624 # 04 Y:2001 | 04 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $281 | $500 | Not Implemented |
UD0620 # 01 Y:2001 | 01 | 2001 | RECOVER AND REUSE SPENT ACID BATHS | $42,596 | $85,000 | Not Implemented |
UD0620 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,449 | $300 | Not Implemented |
UD0620 # 03 Y:2001 | 03 | 2001 | RECOVER AND REUSE SPENT ACID BATHS | $2,250 | $0 | Not Implemented |
UD0620 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,850 | $0 | Not Implemented |
UD0620 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,470 | $3,648 | Implemented |
UD0620 # 06 Y:2001 | 06 | 2001 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,218 | $0 | Implemented |
UD0620 # 07 Y:2001 | 07 | 2001 | MINIMIZE WATER USAGE | $876 | $750 | Not Implemented |
UD0620 # 08 Y:2001 | 08 | 2001 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $756 | $0 | Implemented |
UD0508 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $7,200 | $60,000 | Implemented |
UD0508 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,088 | $2,314 | Implemented |
UD0508 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,041 | $8,081 | Implemented |
UD0508 # 04 Y:1996 | 04 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $31,719 | $11,000 | Implemented |
UD0508 # 05 Y:1996 | 05 | 1996 | ELIMINATE/REDUCE AN OPERATION | $9,650 | $5,000 | Not Implemented |
UD0508 # 06 Y:1996 | 06 | 1996 | ELIMINATE/REDUCE AN OPERATION | $8,523 | $0 | Implemented |
UD0508 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $101,584 | $40,000 | Implemented |
UD0508 # 08 Y:1996 | 08 | 1996 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $135,600 | $222,868 | Implemented |
UD0508 # 09 Y:1996 | 09 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,158 | $2,286 | Implemented |
UD0508 # 10 Y:1996 | 10 | 1996 | RECOVER AND REUSE COOLING WATER | $5,108 | $5,000 | Implemented |
UD0467 # 01 Y:1995 | 01 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $68,000 | $72,000 | Implemented |
UD0467 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,434 | $3,000 | Implemented |
UD0467 # 03 Y:1995 | 03 | 1995 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,135 | $150,000 | Not Implemented |
UD0405 # 01 Y:1993 | 01 | 1993 | UPGRADE CONTROLS ON COMPRESSORS | $2,213 | $100 | Implemented |
UD0405 # 02 Y:1993 | 02 | 1993 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,743 | $2,000 | Implemented |
UD0405 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,176 | $2,511 | Implemented |